 浏览型号TMXF281553BAL-3C-DB的Datasheet PDF文件第557页浏览型号TMXF281553BAL-3C-DB的Datasheet PDF文件第558页浏览型号TMXF281553BAL-3C-DB的Datasheet PDF文件第559页浏览型号TMXF281553BAL-3C-DB的Datasheet PDF文件第560页浏览型号TMXF281553BAL-3C-DB的Datasheet PDF文件第562页浏览型号TMXF281553BAL-3C-DB的Datasheet PDF文件第563页浏览型号TMXF281553BAL-3C-DB的Datasheet PDF文件第564页浏览型号TMXF281553BAL-3C-DB的Datasheet PDF文件第565页  
Data Sheet  
June 2002  
TMXF28155 Supermapper  
155/51 Mbits/s SONET/SDH x28/x21 DS1/E1  
22 Cross Connect (XC) Block Functional Description (continued)  
22.6.5 Framer Interface  
The framer block can pass through a total bandwidth of one DS3. This may be formed from 28 DS1s or 21 E1s, or  
any mix where a group of four adjacent DS1 channels may be substituted by three E1s. The DS1 or E1 channels  
can be cross connected to the M13 MUX, VT mapper, external I/O interface, or test interface. The framer block pro-  
vides extensive per-link loopback capability based on DS1/E1 standards.  
As previously stated, special channels for AIS, RAI, frame sync, and signaling are enabled when the framer is  
cross connected to the VT mapper.  
The framer presents six interfaces to the cross connect as shown in Figure 83 on page 553. Although somewhat  
flexible, most applications will cross connect the framer interfaces FRM_TP_T (XC1—source ID = 010) and  
FRM_RP_R (XC1—destination = XC_RP_RDATA[1—28][7:0] (Table 464 on page 328)) to the M13 MUX or VT  
mapper. If desired, the digital jitter attenuators may be inserted in this connection.  
An example of an exception to this rule is the framer-only application where the Supermapper is used as a block of  
28 framers with a CHI system interface. The 28 framers would interface line interface units with FRM_TP_T and  
FRM_RP_R and the system with FRM_TS and FRM_RS entirely through the multifunction system interface device  
pins.  
Either end of the framer block may be configured to interface to line interface units as shown in Figure 86. In a  
framer-only application, the FRM_TP_T and FRM_RP_R framer block interfaces with the LIUs. The FRM_RP_T  
and FRM_TP_R framer block interfaces the LIUs in a transport application. If a dual-rail or bipolar LIU interface is  
desired, the sync line is used as the negative-rail data.  
The user configures the framer block connectivity by simply loading the appropriate source IDs into the  
XC_TP_RDATA[1—28][7:0] (Table 468 on page 329), XC_RP_RDATA[1—28][7:0], and XC_RS_D[1—28][7:0]  
(Table 469 on page 329) bytes of the framer crosspoint configuration registers: XC_FTP_SRC[1—28][7:0],  
XC_FRP_SRC[1—28][7:0], and XC_FRS_SRC[1—28][7:0], respectively.  
XC  
EXTERNAL I/O  
XC_TP_RDATA[1—28][7:0]  
3x28  
FRM  
FRM_TP_R  
XC_TP_RDATA  
XC_TP_RCLK  
XC_TP_RFS  
LINERXDATA  
LINERXCLK  
3x29  
FRM_RP_R  
3x28  
LINERXSYNC  
XC_RP_RDATA  
XC_RP_RCLK  
XC_RP_RFS  
XC_RP_RDATA[1—28][7:0]  
FRM_TP_T  
FRM_TP_TDATA  
FRM_TP_TCLK  
FRM_TP_TFS  
3x28  
3x28  
LINETXDATA  
LINETXCLK  
XC_PDATA[1—29][7:0]  
3x29  
FRM_RP_T  
FRM_RP_TDATA  
FRM_RP_TCLK  
FRM_RP_TFS  
LINETXSYNC  
XC_SYNC[1—29][7:0]  
XC1  
5-9184(F)r.1  
Figure 86. Framer Line Interface Cross Connect  
Agere Systems Inc.  
561