Si3210/Si3211/Si3212  
Table 4. Linefeed Characteristics  
(V  
, V  
= 3.13 to 5.25 V, T = 0 to 70°C for K-Grade, –40 to 85°C for B-Grade)  
DDA  
DDD A  
Parameter  
Symbol  
Test Condition  
Min  
Typ  
Max  
Unit  
Loop Resistance Range  
R
See note.*  
0
160  
10  
4
%
V
LOOP  
DC Loop Current Accuracy  
I
= 29 mA, ETBA = 4 mA  
–10  
–4  
LIM  
DC Open Circuit Voltage  
Accuracy  
Active Mode; V  
= 48 V,  
OC  
V
– V  
TIP  
RING  
DC Differential Output  
Resistance  
R
I
< I  
LIM  
–4  
160  
4
V
DO  
LOOP  
DC Open Circuit Voltage—  
Ground Start  
V
R
I
<I ; V  
wrt ground  
RING  
= 48 V  
OCTO  
ROTO  
RING LIM  
V
OC  
DC Output Resistance—  
Ground Start  
I
<I ; RING to ground  
160  
RING LIM  
DC Output Resistance—  
Ground Start  
R
TIP to ground  
= 11.43 mA  
150  
–20  
–20  
kΩ  
%
%
TOTO  
Loop Closure/Ring Ground  
Detect Threshold Accuracy  
I
20  
20  
THR  
Ring Trip Threshold  
Accuracy  
R
= 1100 Ω  
THR  
Ring Trip Response Time  
User Programmable Register 70  
and Indirect Register 36  
Ring Amplitude  
V
R
5 REN load; sine wave;  
44  
V
RMS  
TR  
R
= 160 Ω, V  
= –75 V  
LOOP  
BAT  
Ring DC Offset  
Programmable in Indirect  
Register 19  
0
V
OS  
Trapezoidal Ring Crest  
Factor Accuracy  
Crest factor = 1.3  
–.05  
1.35  
.05  
1.45  
Sinusoidal Ring Crest  
Factor  
R
CF  
Ringing Frequency Accuracy  
Ringing Cadence Accuracy  
Calibration Time  
f = 20 Hz  
–1  
–50  
1
%
Accuracy of ON/OFF Times  
CAL to CAL Bit  
50  
msec  
msec  
%
600  
25  
Power Alarm Threshold  
Accuracy  
At Power Threshold = 300 mW  
–25  
*Note: DC resistance round trip; 160 corresponds to 2 kft 26 gauge AWG.  