ZMD31020
Sensor Signal Conditioner
Datasheet
Timing Characteristics of the serial Interface
tI2C_F
tI2C_SU_DAT
tI2C_HD_DAT
tI2C_SU_STA tI2C_HD_STA tI2C_R
tI2C_H tI2C_L
tI2C_HD_STA
tI2C_SU_STO tI2C_BF
PARAMETER
SYMBOL
fSCL
CONDITIONS
MIN
-
TYP
MAX
UNIT
kHz
µs
SCL clock frequency
100
Bus free time betw. STOP
and START condition
tI2C_BF
4.7
Hold Time (repeated)
START cond.
tI2C_HD_STA to first clock pulse
4.0
µs
LOW period of SCL
HIGH period of SCL
tI2C_L
tI2C_H
4.7
4.0
4.7
µs
µs
µs
Setup time (repeated)
START cond.
tI2C_SU_STA
Data hold time
Data setup time
tI2C_HD_DAT
tI2C_SU_DAT
tI2C_R
0
250
-
ns
ns
ns
Rise time of both SDA and
SCL
300
Fall time of both SDA and
SCL
tI2C_F
-
300
ns
µs
ns
Setup time for STOP
condition
tI2C_SU_STO
4
Input filter spike
suppression / noise
interception
tI2C_NI
spikes on SDA or
SCL of that length
are suppressed
50
Copyright © 2004, ZMD AG, Rev. 1.6, 2005-05-19
13/19
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior
written consent of the copyright owner. The Information furnished in this publication is preliminary and subject to changes without notice.