 浏览型号Z8FMC04100QKSG的Datasheet PDF文件第120页浏览型号Z8FMC04100QKSG的Datasheet PDF文件第121页浏览型号Z8FMC04100QKSG的Datasheet PDF文件第122页浏览型号Z8FMC04100QKSG的Datasheet PDF文件第123页浏览型号Z8FMC04100QKSG的Datasheet PDF文件第125页浏览型号Z8FMC04100QKSG的Datasheet PDF文件第126页浏览型号Z8FMC04100QKSG的Datasheet PDF文件第127页浏览型号Z8FMC04100QKSG的Datasheet PDF文件第128页  
Z8 Encore!® Motor Control Flash MCUs  
Product Specification  
102  
The timer counts up to the 16-bit reload value stored in the Timer Reload High and Low  
Byte registers. When reaching the reload value, the timer generates an interrupt, the count  
value in the Timer High and Low Byte registers is reset to 0001h, and counting continues  
as long as the Timer Input signal is active. Also, if the Timer Output alternate function is  
enabled, the Timer Output pin changes state (from Low to High or from High to Low) at  
timer reload.  
The steps for configuring a timer for GATED mode and initiating the count are as follows:  
1. Write to the Timer Control registers to:  
a. Disable the timer.  
b. Configure the timer for GATED mode.  
c. Set the prescale value.  
d. Select the active state of the Timer Input via the TPOLbit.  
2. Write to the Timer High and Low Byte registers to set the starting count value. This  
setting only affects the first pass in GATED mode. After the first timer reset in  
GATED mode, counting begins at the reset value of 0001h.  
3. Write to the Timer Reload High and Low Byte registers to set the reload value.  
4. If appropriate, enable the timer interrupt and set the timer interrupt priority by writing  
to the relevant interrupt registers.  
5. Configure the timer interrupt to be generated only at the input deassertion event, the  
reload event, or both, by setting the TICONFIGfield of the Timer Control 0 Register.  
6. Configure the associated GPIO port pin for the Timer Input alternate function.  
7. Write to the Timer Control 1 Register to enable the timer.  
8. The timer counts when the Timer Input is equal to the TPOLbit.  
Reading the Timer Count Values  
The current count value in the timers can be read while counting (enabled). This Read has  
no effect on timer operation. When the timer is enabled and the Timer High Byte Register  
is read, the contents of the Timer Low Byte Register are placed into a holding register. A  
subsequent Read from the Timer Low Byte Register returns the value in the holding regis-  
ter. This operation allows accurate Reads of the full 16-bit timer count value while  
enabled. When the timer is not enabled, a Read from the Timer Low Byte Register returns  
the actual value in the counter.  
Timer 0 High and Low Byte Registers  
The Timer 0 High and Low Byte (T0H and T0L) registers, shown in Tables 58 and 59,  
contain the current 16-bit timer count value. When the timer is enabled, a Read from T0H  
General-Purpose Timer  
P R E L I M I N A R Y  