 浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第92页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第93页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第94页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第95页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第97页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第98页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第99页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第100页  
eZ80L92 MCU  
Product Specification  
83  
6
0
1
0
0
Timer interrupt requests are disabled.  
Timer interrupt requests are enabled.  
Reserved.  
IRQ_EN  
5
4
The timer operates in SINGLE PASS mode. PRT_EN (bit 0) is  
reset to 0, and counting stops when the end-of-count value is  
reached.  
PRT_MODE  
1
The timer operates in CONTINUOUS mode. The timer reload  
value is written to the counter when the end-of-count value is  
reached.  
[3:2]  
CLK_DIV  
00  
01  
10  
11  
0
Clock ÷ 4 is the timer input source.  
Clock ÷ 16 is the timer input source.  
Clock ÷ 64 is the timer input source.  
Clock ÷ 256 is the timer input source.  
The reload and restart function is disabled.  
1
RST_EN  
1
The reload and restart function is enabled. When a 1 is written to  
RST_EN, the values in the reload registers are loaded into the  
downcounter and the timer restarts.  
0
0
1
The programmable reload timer is disabled.  
The programmable reload timer is enabled.  
PRT_EN  
Timer Data Registers—Low Byte  
This Read-Only register returns the Low byte of the current count value of the selected  
timer. The Timer Data Register—Low Byte, detailed in Table 33, can be read while the  
timer is in operation. Reading the current count value does not affect timer operation. To  
read the 16-bit data of the current count value, {TMRx_DR_H[7:0], TMRx_DR_L[7:0]},  
first read the Timer Data Register—Low Byte and then read the Timer Data Regis-  
ter—High Byte. The Timer Data Register—High Byte value is latched when a Read of the  
Timer Data Register—Low Byte occurs.  