欢迎访问ic37.com |
会员登录 免费注册
发布采购

EZ80L92AZ020SC00TR 参数 Datasheet PDF下载

EZ80L92AZ020SC00TR图片预览
型号: EZ80L92AZ020SC00TR
PDF下载: 下载PDF文件 查看货源
内容描述: [IC MCU 8BIT ROMLESS 100LQFP]
分类和应用:
文件页数/大小: 238 页 / 1067 K
品牌: ZILOG [ ZILOG, INC. ]
 浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第89页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第90页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第91页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第92页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第94页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第95页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第96页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第97页  
eZ80L92 MCU  
Product Specification  
80  
Table 30. PRT CONTINUOUS Mode Operation Example  
Parameter  
Control Register(s)  
TMRx_CTL[0]  
TMRx_CTL[1]  
TMRx_CTL[3:2]  
TMRx_CTL[4]  
TMRx_CTL[6]  
Value  
PRT Enabled  
1
1
Reload and Restart Enabled  
PRT Clock Divider = 4  
CONTINUOUS Mode  
PRT Interrupt Enabled  
PRT Reload Value  
00b  
1
1
{TMRx_RR_H, TMRx_RR_L}  
0004h  
Reading the Current Count Value  
The CPU is capable of reading the current count value while the timer is running. This  
Read event does not affect timer operation. The High byte of the current count value is  
latched during a Read of the Low byte.  
Timer Interrupts  
The timer interrupt flag, PRT_IRQ, is set to 1 whenever the timer reaches its end-of-count  
value, 0000h, in SINGLE PASS mode, or when the timer reloads the start value in  
CONTINUOUS mode. The interrupt flag is only set when the timer reaches 0000h (or  
reloads) from 0001h. The timer interrupt flag is not set to 1 when the timer is loaded with  
the value 0000h, which selects the maximum time-out period.  
The CPU can be programmed to poll the PRT_IRQ bit for the time-out event. Alterna-  
tively, an interrupt service request signal can be sent to the CPU by setting IRQ_EN to 1.  
Then, when the end-of-count value, 0000h, is reached and PRT_IRQ is set to 1, an  
interrupt service request signal is passed to the CPU. PRT_IRQ is cleared to 0 and the  
interrupt service request signal is inactivated whenever the CPU reads from the timer con-  
trol registers, TMRx_CTL.  
Timer Input Source Selection  
Timers 0–3 feature programmable input source selection. By default, the input is taken  
from the ZLP12840’s system clock. Alternatively, Timers 0–3 can take their input from  
port input pins PB0 (Timers 0 and 2) or PB1 (Timers 1 and 3). Timers 0–3 can also use the  
Real-Time Clock clock source (50, 60, or 32768 Hz) as their clock sources. When the  
timer clock source is the Real-Time Clock signal, the timer decrements on the second  
rising edge of the system clock following the falling edge of the RTC_XOUT pin. The  
input source for these timers is set using the Timer Input Source Select register.  
PS013015-0316  
Programmable Reload Timers  
 复制成功!