 浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第133页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第134页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第135页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第136页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第138页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第139页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第140页浏览型号EZ80L92AZ020SC00TR的Datasheet PDF文件第141页  
eZ80L92 MCU  
Product Specification  
124  
For more information on the UART and its Baud Rate Generator, see Universal Asynchro-  
nous Receiver/Transmitter on page 104.  
Transmit  
The data to be transmitted via the IR transceiver is first sent to UART0. The UART  
transmit signal (TxD) and Baud Rate Clock are used by the infrared encoder/decoder to  
generate the modulation signal (IR_TXD) that drives the infrared transceiver. Each UART  
bit is 16-clocks wide. If the data to be transmitted is a logical 1 (High), the IR_TXD signal  
remains Low (0) for the full 16-clock period. If the data to be transmitted is a logical 0, a  
3-clock High (1) pulse is output following a 7-clock Low (0) period. Following the  
3-clock High pulse, a 6-clock Low pulse completes the full 16-clock data period. Data  
transmission is illustrated in Figure 25. During data transmission, the IR receive function  
should be disabled by clearing the IR_RXEN bit in the IR_CTL reg to 0. This prevents  
transmitter to receiver cross-talk.  
16-clock  
period  
Baud Rate  
Clock  
UART_TxD  
Start Bit = 0  
Data Bit 0 = 1  
Data Bit 1 = 0  
Data Bit 2 = 1  
Data Bit 3 = 1  
3-clock  
pulse  
IR_TxD  
7-clock  
delay  
Figure 25. Infrared Data Transmission  
Receive  
Data received from the IR transceiver via the IR_RXD signal is decoded by the infrared  
encoder/decoder and passed to the UART. The IR_RXEN bit in the IR_CTL register must  
be set to enable the receiver decoder. The SIR data format uses half duplex communica-  
tion therefore the UART should not be allowed to transmit while the receiver decoder is  
enabled. The UART Baud Rate Clock is used by the infrared encoder/decoder to generate  
the demodulated signal (RxD) that drives the UART. Each UART bit is 16-clocks wide. If  
the data to be received is a logical 1 (High), the IR_RXD signal remains High (1) for the  
full 16-clock period. If the data to be received is a logical 0, a 3-clock Low (0) pulse is  