 浏览型号WM8904CGEFL/V的Datasheet PDF文件第116页浏览型号WM8904CGEFL/V的Datasheet PDF文件第117页浏览型号WM8904CGEFL/V的Datasheet PDF文件第118页浏览型号WM8904CGEFL/V的Datasheet PDF文件第119页浏览型号WM8904CGEFL/V的Datasheet PDF文件第121页浏览型号WM8904CGEFL/V的Datasheet PDF文件第122页浏览型号WM8904CGEFL/V的Datasheet PDF文件第123页浏览型号WM8904CGEFL/V的Datasheet PDF文件第124页  
WM8904  
Pre-Production  
DESCRIPTION  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
R128 (80h)  
Interrupt  
Status Mask  
GPIO4 interrupt mask  
0 = do not mask interrupt  
1 = mask interrupt  
9
IM_GPIO_BCLK_EINT  
1
Write sequencer interrupt  
mask  
8
IM_WSEQ_EINT  
1
0 = do not mask interrupt  
1 = mask interrupt  
GPIO3 interrupt mask  
0 = do not mask interrupt  
1 = mask interrupt  
7
6
5
4
3
2
1
IM_GPIO3_EINT  
IM_GPIO2_EINT  
IM_GPIO1_EINT  
IM_GPI8_EINT  
1
1
1
1
1
1
1
GPIO2 interrupt mask  
0 = do not mask interrupt  
1 = mask interrupt  
GPIO1 interrupt mask  
0 = do not mask interrupt  
1 = mask interrupt  
GPI8 interrupt mask  
0 = do not mask interrupt  
1 = mask interrupt  
GPI7 interrupt mask  
0 = do not mask interrupt  
1 = mask interrupt  
IM_GPI7_EINT  
FLL Lock interrupt mask  
0 = do not mask interrupt  
1 = mask interrupt  
IM_FLL_LOCK_EINT  
IM_MIC_SHRT_EINT  
MICBIAS short circuit interrupt  
mask  
0 = do not mask interrupt  
1 = mask interrupt  
MICBIAS current detect  
interrupt mask  
0
IM_MIC_DET_EINT  
1
0 = do not mask interrupt  
1 = mask interrupt  
Table 80 Interrupt Mask Registers  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
R129 (81h)  
Interrupt  
Polarity  
GPIO4 interrupt polarity  
0 = active high  
9
GPIO_BCLK_EINT_POL  
0
1 = active low  
Write Sequencer interrupt  
polarity  
8
7
WSEQ_EINT_POL  
GPIO3_EINT_POL  
0
0
0 = active high (interrupt is  
triggered when WSEQ is  
busy)  
1 = active low (interrupt is  
triggered when WSEQ is idle)  
GPIO3 interrupt polarity  
0 = active high  
1 = active low  
PP, Rev 3.3, September 2012  