WM8352
Production Data
REFER TO
REGISTER
ADDRESS
BIT
LABEL
DEFAULT
DESCRIPTION
3
DC5_RMPL
1
DC-DC5 compensation ramp
{DC5_RMPH, DC5_RMPL}
00 = 20V < VOUT ≤ 30V
01 = 10V < VOUT ≤ 20V
10 = 5V < VOUT ≤ 10V
11 = VOUT ≤ 5V (will be chosen automatically if
DC5_FBSRC=11)
Reset by state machine. Default held in metal
mask.
1:0
DC5_FBSRC[1:0]
00
DC-DC5 voltage feedback selection
00 = voltage feedback (using external resistor
divider on pin FB5)
01 = current sink ISINKA used as feedback
10 = current sink ISINKB used as feedback
11 = voltage feedback (using internal resistor
divider on pin USB)
Reset by state machine. Default held in metal
mask.
Register C0h DCDC5 Control
REGISTER
ADDRESS
BIT
LABEL
DEFAULT
DESCRIPTION
REFER TO
R193 (C1h)
DCDC5
15:14 DC5_ERRACT[1:0]
00
Action to take on DC-DC5 fault (as well as
generating an interrupt):
Timeouts
00 = ignore
01 = shut down converter
10 = shut down system
11 = reserved (shut down system)
Reset by state machine. Default held in metal
mask.
13:10 DC5_ENSLOT[3:0]
0000
Time slot for DC-DC5 start-up
0000 = Disabled (do not start up)
0001 = Start-up in time slot 1
… (total 14 slots available)
1110 = Start-up in time slot 14
1111 = Start-up on entering ACTIVE
Reset by state machine. Default held in metal
mask.
9:6
DC5_SDSLOT[3:0]
0000
Time slot for DC-DC5 shutdown.
0000 = Shut down on entering OFF
0001 = Shutdown in time slot 1
…. (total 14 slots available)
1110 = Shutdown in time slot 14
1111 = Shut down on entering OFF
Register C1h DCDC5 Timeouts
PD, February 2011, Rev 4.4
302