WM8352  
Production Data  
REFER TO  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
8
LDO1_ENA  
0
LDO1 enable  
0 = disabled  
1 = enabled  
Note: internal conditions may prevent the converter  
from actually switching on - see DCDC/LDO Status  
register for actual converter status.  
Reset by state machine. Default held in metal mask.  
DCDC6 converter enable  
0 = disabled  
5
4
3
2
1
0
DC6_ENA  
DC5_ENA  
DC4_ENA  
DC3_ENA  
DC2_ENA  
DC1_ENA  
0
0
0
0
0
0
1 = enabled  
Note: internal conditions may prevent the converter  
from actually switching on - see DCDC/LDO Status  
register for actual converter status.  
Reset by state machine. Default held in metal mask.  
DCDC5 converter enable  
0 = disabled  
1 = enabled  
Note: internal conditions may prevent the converter  
from actually switching on - see DCDC/LDO Status  
register for actual converter status.  
Reset by state machine. Default held in metal mask.  
DCDC4 converter enable  
0 = disabled  
1 = enabled  
Note: internal conditions may prevent the converter  
from actually switching on - see DCDC/LDO Status  
register for actual converter status.  
Reset by state machine. Default held in metal mask.  
DCDC3 converter enable  
0 = disabled  
1 = enabled  
Note: internal conditions may prevent the converter  
from actually switching on - see DCDC/LDO Status  
register for actual converter status.  
Reset by state machine. Default held in metal mask.  
DCDC2 converter enable  
0 = disabled  
1 = enabled  
Note: internal conditions may prevent the converter  
from actually switching on - see DCDC/LDO Status  
register for actual converter status.  
Reset by state machine. Default held in metal mask.  
DCDC1 converter enable  
0 = disabled  
1 = enabled  
Note: internal conditions may prevent the converter  
from actually switching on - see DCDC/LDO Status  
register for actual converter status.  
Reset by state machine. Default held in metal mask.  
Register 0Dh Power mgmt (6)  
PD, February 2011, Rev 4.4  
228  