W83697HF/F  
5.1.7 Bank0.Reg6 - Remote Infrared Config Register (RIR_CFG), continued  
Power on default <7:0> = 0000,0000 binary  
Bit  
Name  
Read/Write  
Description  
Low pass filter source selcetion.  
5-4  
LP_SL<1:0>  
Read/Write  
LP_SL<1:0> = 00 Select raw IRRX signal.  
LP_SL<1:0> = 01 Select R.B.P. signal  
LP_SL<1:0> = 10 Select D.B.P. signal.  
LP_SL<1:0> = 11 Reserved.  
Receiver Demodulation Source Selection.  
RXDMSL<1:0> = 00 select B.P. and L.P. filter.  
RXDMSL<1:0> = 01 select B.P. but not L.P.  
RXDMSL<1:0> = 10 Reserved.  
3-2  
RXDMSL<1:0>  
Read/Write  
RXDMSL<1:0> = 11 do not pass demodulation.  
Baud Rate Pre-divisor. Set to 1, the baud rate generator  
input clock is set to 1.8432M Hz which is set to pre-divisor  
into 13. When set to 0, the pre-divisor is set to 1, that is,  
the input clock of baud rate generator is set to 24M Hz.  
Receiving Signal Invert. Write to 1, Invert the receiving  
signal.  
1
0
PRE_DIV  
RXINV  
Read/Write  
Read/Write  
5.1.8 Bank0.Reg7 - User Defined Register (UDR/AUDR)  
Power on default <7:0> = 0000,0000 binary  
Bit  
Name  
RXACT  
Read/Write  
Description  
7
Read/Write Receive Active. Set to 1 whenever a pulse or pulse-train is  
detected by the receiver. If a 1 is written into the bit  
position, the bit is cleared and the receiver is de-actived.  
When this bit is set, the receiver samples the IR input  
continuously at the programmed baud rate and transfers  
the data to the receiver FIFO.  
6
RX_PD  
Read Only  
Set to 1 whenever a pulse or pulse-train (modulated pulse)  
is detected by the receiver. Can be used by the sofware to  
detect idle condition Cleared Upon Read.  
5
Reserved  
FOLVAL  
-
-
4-0  
Read Only  
FIFO Level Value. Indicate that how many bytes are there  
in the current received FIFO. Can read these bits then get  
the FIFO level value and successively read RBR by the  
prior value.  
Publication Release Date: Feb. 2002  
- 60 -  
Revision 0.70  