W25Q128BV
8. ELECTRICAL CHARACTERISTICS
(1)
8.1 Absolute Maximum Ratings
PARAMETERS
SYMBOL
VCC
CONDITIONS
RANGE
UNIT
Supply Voltage
–0.6 to +4.6
V
V
V
Voltage Applied to Any Pin
Transient Voltage on any Pin
VIO
Relative to Ground
–0.6 to VCC+0.4
–2.0V to VCC+2.0V
VIOT
<20nS Transient
Relative to Ground
Storage Temperature
TSTG
TLEAD
VESD
–65 to +150
See Note (2)
°C
°C
V
Lead Temperature
Electrostatic Discharge Voltage
Human Body Model(3) –2000 to +2000
Notes:
1. This device has been designed and tested for the specified operation ranges. Proper operation outside
of these levels is not guaranteed. Exposure to absolute maximum ratings may affect device reliability.
Exposure beyond absolute maximum ratings may cause permanent damage.
2. Compliant with JEDEC Standard J-STD-20C for small body Sn-Pb or Pb-free (Green) assembly and the
European directive on restrictions on hazardous substances (RoHS) 2002/95/EU.
3. JEDEC Std JESD22-A114A (C1=100pF, R1=1500 ohms, R2=500 ohms).
8.2 Operating Ranges
SPEC
PARAMETER
SYMBOL
CONDITIONS
UNIT
MIN
MAX
FR = 70MHz (Dual I/O & Quad SPI)
FR = 104MHz (Single SPI & Dual Output)
fR = 33MHz
Supply Voltage(1)
VCC
TA
2.7V
3.6V
V
Ambient Temperature,
Operating
Industrial
Automotive
-40
-40
+85
+105
°C
Note:
1. VCC voltage during Read can operate across the min and max range but should not exceed ±10% of
the programming (erase/write) voltage.