Preliminary W24100
AC Characteristics, continued
(VDD = 5V 10%; VSS = 0V; TA = 0 C to 70 C)
±
°
°
Read Cycle
PARAMETER
SYM.
W24100-70L
W24100-70LL
UNIT
MIN.
MAX.
MIN.
MAX.
RC
Read Cycle Time
T
70
-
-
70
-
-
nS
nS
nS
nS
nS
nS
nS
nS
nS
AA
Address Access Time
Chip Select Access Time
T
T
T
T
T
T
T
T
70
70
35
-
70
70
35
-
ACS
AOE
CLZ
-
-
Output Enable to Output Valid
-
-
Chip Selection to Output in Low Z
Output Enable to Output in Low Z
Chip Deselection to Output in High Z
Output Disable to Output in High Z
Output Hold from Address Change
These parameters are sampled but not 100% tested
*
10
5
10
5
OLZ
*
-
-
CHZ
*
-
30
30
-
-
30
30
-
OHZ
OH
*
-
-
10
10
*
Write Cycle
PARAMETER
SYM.
W24100-70L
W24100-70LL
UNIT
MIN.
70
50
50
0
MAX.
MIN.
70
50
50
0
MAX.
WC
Write Cycle Time
T
-
-
-
-
-
-
-
-
-
-
-
-
nS
nS
nS
nS
nS
nS
CW
T
AW
T
AS
T
T
T
Chip Selection to End of Write
Address Valid to End of Write
Address Setup Time
WP
WR
Write Pulse Width
50
0
50
0
Write Recovery Time
WE
CS1, CS2,
DW
Data Valid to End of Write
T
T
T
T
T
30
0
-
-
-
30
0
-
-
-
nS
nS
nS
nS
nS
DH
Data Hold from End of Write
Write to Output in High Z
WHZ
OHZ
*
25
25
-
25
25
-
Output Disable to Output in High Z
Output Active from End of Write
*
-
-
OW
5
5
These parameters are sampled but not 100% tested
*
- 4 -