Preliminary W24100
CAPACITANCE
DD
A
(V = 5 V, T = 25 C, f = 1 MHz)
°
PARAMETER
Input Capacitance
SYM.
CONDITIONS
MAX.
UNIT
pF
IN
C
IN
V
= 0V
6
8
I/O
C
OUT
V = 0V
Input/Output Capacitance
pF
Note: These parameters are sampled but not 100% tested.
AC CHARACTERISTICS
AC Test Conditions
PARAMETER
Input Pulse Levels
CONDITIONS
0V to 3.0V
5 nS
Input Rise and Fall Times
Input and Output Timing Reference Level
Output Load
1.5V
See the drawing below
AC Test Loads and Waveform
1 TTL
1 TTL
OUTPUT
OUTPUT
5 pF
100 pF
Including
Jig and
Scope
Including
Jig and
Scope
(For T
T
T
T
T
T
)
CLZ, OLZ, CHZ, OHZ, WHZ, OW
90%
10%
5 nS
3.0V
90%
10%
0V
5 nS
Publication Release Date: October 1999
Revision A1
- 3 -