Preliminary W24100
TRUTH TABLE
CS2
CS1
MODE
Not Selected
Not Selected
Output Disable
Read
VDD CURRENT
I/O1
High Z
High Z
High Z
-I/O8
OE
X
WE
X
SB SB
H
X
L
L
L
X
L
I
I
I
I
I
, I
1
1
SB SB
X
X
, I
DD
DD
DD
H
H
H
H
L
H
H
Data Out
Data In
X
L
Write
DC CHARACTERISTICS
Absolute Maximum Ratings
PARAMETER
RATING
UNIT
V
SS
Supply Voltage to V Potential
-0.5 to +7.0
SS
DD
Input/Output to V Potential
-0.5 to V +0.5
V
Allowable Power Dissipation
Storage Temperature
1.0
W
-65 to +150
0 to 70
°
°
C
Operating Temperature
C
Note: Exposure to conditions beyond those listed under Absolute Maximum Ratings may adversely affect the life and reliability of the
device.
Operating Characteristics
DD
SS
A
(V = 5V 10%; V = 0V; T = 0 C to 70 C)
±
°
°
PARAMETER
Input Low Voltage
Input High Voltage
Input Leakage Current
SYM.
TEST CONDITIONS
MIN.
-0.5
+2.2
-1
TYP.*
MAX.
+0.8
DD
UNIT
V
IL
V
-
-
-
-
-
-
IH
V
V
+0.5
V
LI
IN
SS
DD
I
V
= V to V
+1
+1
m
A
Output Leakage
Current
LO
I
-1
m
A
I/O
V
SS
DD,
IH
= V
CS1
= V to V
OE
IH
= V (min.)
(min.) or
WE
IL
or
= V (max.)
Output Low Voltage
Output High Voltage
OL
OL
= +2.1 mA
V
I
I
-
2.4
-
-
-
-
0.4
-
V
OH
OH
= -1.0 mA
V
V
Operating Power
Supply Current
DD
I
70
mA
IL
CS1
= V (max.) and
IH
CS2 = V (min.), I/O = 0 mA
Cycle = min., Duty = 100%
Standby Power Supply
Current
SB
I
-
-
3
mA
IH
CS
= V (min.), Cycle = min.
Duty = 100%
-
-
SB
I
1
LL
L
-
-
50
m
A
DD
CS1 ³
V
-0.2V or
100
£
CS2 0.2V
Note: Typical parameter is measured under ambient temperature TA = 25 C and VDD = 5V.
°
- 2 -