W25M02GV  
8.2.27 Accessing Unique ID / Parameter / OTP Pages (OTP-E=1)  
In addition to the main memory array, each of the stacked W25N01GV die is also equipped with one  
Unique ID Page, one Parameter Page, and ten OTP Pages.  
Page Address  
Page Name  
Descriptions  
Data Length  
00h  
01h  
02h  
Unique ID Page  
Parameter Page  
OTP Page [0]  
OTP Pages [1:8]  
OTP Page [9]  
Factory programmed, Read Only  
Factory programmed, Read Only  
Program Only, OTP lockable  
Program Only, OTP lockable  
Program Only, OTP lockable  
32-Byte x 16  
256-Byte x 3  
2,112-Byte  
2,112-Byte  
2,112-Byte  
0Bh  
To access these additional data pages, the OTP-E bit in Status Register-2 must be set to “1” first. Then,  
Read operations can be performed on Unique ID and Parameter Pages, Read and Program operations  
can be performed on the OTP pages if it’s not already locked. To return to the main memory array  
operation, OTP-E bit needs to be to set to 0.  
Read Operations  
A “Page Data Read” command must be issued followed by a specific page address shown in the table  
above to load the page data into the main Data Buffer. After the device finishes the data loading  
(BUSY=0), all Read commands may be used to read the Data Buffer starting from any specified Column  
Address. Please note all Read commands must now follow the “Buffer Read Mode” command structure  
(CA[15:0], number of dummy clocks) regardless the previous BUF bit setting. ECC can also be enabled  
for the OTP page read operations to ensure the data integrity.  
Program and OTP Lock Operations  
OTP pages provide the additional space (2K-Byte x 10) to store important data or security information that  
can be locked to prevent further modification in the field. These OTP pages are in an erased state set in  
the factory, and can only be programmed (change data from “1” to “0”) until being locked by OTP-L bit in  
the Configuration/Status Register-2. OTP-E must be first set to “1” to enable the access to these OTP  
pages, then the program data must be loaded into the main Data Buffer using any “Program Data Load”  
commands. The “Program Execute” command followed by a specific OTP Page Address is used to initiate  
the data transfer from the Data Buffer to the OTP page. When ECC is enabled, ECC calculation will be  
performed during “Program Execute”, and the ECC information will be stored into the 64-Byte spare area.  
Once the OTP pages are correctly programmed, OTP-L bit can be used to permanently lock these pages  
so that no further modification is possible. While still in the “OTP Access Mode” (OTP-E=1), user needs to  
set OTP-L bit in the Configuration/Status Register-2 to “1”, and issue a “Program Execute” command  
without any Page Address. After the device finishes the OTP lock setting (BUSY=0), the user can set  
OTP-E to “0” to return to the main memory array operation.  
SR1-L OTP Lock Operation  
The Protection/Status Register-1 contains protection bits that can be set to protect either a portion or the  
entire memory array from being Programmed/Erased or set the device to either Software Write Protection  
(WP-E=0) or Hardware Write Protection (WP-E=1). Once the BP[3:0], TB, WP-E bits are set correctly,  
SRP1 and SRP0 should also be set to “1”s as well to allow SR1-L bit being set to “1” to permanently lock  
the protection settings in the Status Register-1 (SR1). Similar to the OTP-L setting procedure above, in  
order to set SR1-L lock bit, the device must enter the “OTP Access Mode” (OTP-E=1) first, and SR1-L bit  
should be set to “1” prior to the “Program Execute” command without any Page Address. Once SR1-L is  
set to “1” (BUSY=0), the user can set OTP-E to “0” to return to the main memory array operation.  