TQP3M9008
High Linearity LNA Gain Block
Product Compliance Information
ESD Sensitivity Ratings
Solderability
Compatible with both lead-free (260°C max. reflow
temp.) and lead (245°C max. reflow temp.)
soldering processes.
ESD Rating: 1A
Package lead plating: NiPdAu
Value:
Test:
Standard:
Passes 250V to < 500 V
Human Body Model (HBM)
JEDEC Standard JESD22-A114
RoHs Compliance
This part is compliant with EU 2002/95/EC RoHS
directive (Restrictions on the Use of Certain
Hazardous Substances in Electrical and Electronic
Equipment).
ESD Rating: IV
Value:
Test:
Passes 1000 V
Charged Device Model (CDM)
JEDEC Standard JESD22-C101
Standard:
This product also has the following attributes:
Lead Free
Halogen Free (Chlorine, Bromine)
Antimony Free
TBBP-A (C15H12Br402) Free
PFOS Free
SVHC Free
MSL Classification
MSL Rating: 3
Floor Life:
Test:
168 hours max. at ≤ 30ꢀC / 60% RH
+260 °C convection reflow
Standard:
JEDEC standard IPC/JEDEC J-STD-020
Contact Information
For the latest specifications, additional product information, worldwide sales and distribution locations, and
information about TriQuint:
Web: www.triquint.com
Email: info-sales@tqs.com
Tel:
Fax:
+1.503.615.9000
+1.503.615.8902
For technical questions and application information: Email:sjcapplications.engineering@tqs.com
Important Notice
The information contained herein is believed to be reliable. TriQuint makes no warranties regarding the
information contained herein. TriQuint assumes no responsibility or liability whatsoever for any of the information
contained herein. TriQuint assumes no responsibility or liability whatsoever for the use of the information
contained herein. The information contained herein is provided "AS IS, WHERE IS" and with all faults, and the
entire risk associated with such information is entirely with the user. All information contained herein is subject to
change without notice. Customers should obtain and verify the latest relevant information before placing orders for
TriQuint products. The information contained herein or any use of such information does not grant, explicitly or
implicitly, to any party any patent rights, licenses, or any other intellectual property rights, whether with regard to
such information itself or anything described by such information.
TriQuint products are not warranted or authorized for use as critical components in medical, life-saving, or life-
sustaining applications, or other applications where a failure would reasonably be expected to cause severe
personal injury or death.
Data Sheet: Rev. J
- 10 of 10-
Disclaimer: Subject to change without notice
Connecting the Digital World to the Global Network®
© 2012 TriQuint Semiconductor, Inc.