5.2 MFC IO Control Interface  
The MFC IO block of the TMC8462 comes with a dedicated SPI slave interface to allow direct access from  
a local application controller. It is called MFC CTRL SPI interface. This interface to the MFC IO blocks  
functions is always available, even if the EtherCAT state machine is currently not in operational state (OP).  
Protocol structure and timing are identical to the PDI SPI.  
The MFC Control SPI is a SPI mode 3 slave with low active chip select. The SPI clock frequency can be up to  
30MHz. The following diagram shows all signals related to the MFC CTRL SPI interface.  
Figure 12: MFC control signals  
TMC8462 pin  
Description  
Typical pin on a MCU  
MFC_CTRL_SPI_CSN  
MFC_CTRL_SPI_SCK  
MFC_CTRL_SPI_MOSI  
MFC_CTRL_SPI_MISO  
MFC_IRQ  
SPI chip select for the TMC8462 PDI  
SPI master clock  
SSx  
SCK  
Master out slave in data  
Master in slave out data  
Congurable IRQ from MFC IO block  
MOSI  
MISO  
General purpose Input  
PDI_SHARED_BUS  
0: separate SPI buses for PDI and MFC CTRL; 1:  
shared/common SPI bus for PDI and MFC CTRL  
General purpose Output  
or connected to either  
with 2 CSN signals using the PDI SPI bus. The SPI ground or 3.3V.  
bus signals MFC_CTRL_SPI_SCK,  
MFC_CTRL_SPI_MISO, MFC_CTRL_SPI_MOSI can  
be left open in this case  
Table 5: MFC CTRL SPI signal description  
5.2.1 SPI Protocol description  
The protocol of the MFC CTRL SPI is the same as the PDI SPI interface (see section 5.1.1) The addresses for  
register access are calculated using the register number and the byte number in each register. To calculate  
the address, the register number is shifted left by 4 bits and the byte number is added as the 4 lowest bits.  
Access using the 3 byte addressing mode is possible, and can be used when 2 byte mode is not imple-  
mented for the PDI SPI but since the highest bits of the address are always 0, accessing the MFC Control  
SPI via 2 byte mode is sucient.  