TMC4671 Datasheet • IC Version V1.00 | Document Revision V1.04 • 2018-Dec-11
66 / 157
Address
Registername
Access
Mask
Name
Type
0x000000FFh
ADC_I0_SELECT
Choice
Unit
Min
0
Max
3
Default
0
Select input for raw current ADC_I0_RAW.
0: ADCSD_I0_RAW (sigma delta ADC)
1: ADCSD_I1_RAW (sigma delta ADC)
2: ADC_I0_EXT (from register)
3: ADC_I1_EXT (from register)
Name
Mask
Type
0x0000FF00h
ADC_I1_SELECT
Choice
Unit
Min
0
Max
3
Default
1
Select input for raw current ADC_I1_RAW.
0: ADCSD_I0_RAW (sigma delta ADC)
1: ADCSD_I1_RAW (sigma delta ADC)
2: ADC_I0_EXT (from register)
3: ADC_I1_EXT (from register)
Name
Mask
Type
0x03000000h
ADC_I_UX_SELECT
Choice
Unit
Min
0
Max
2
Default
0
0: UX = ADC_I0 (default)
1: UX = ADC_I1
2: UX = ADC_I2
Name
Mask
Type
0x0C000000h
ADC_I_V_SELECT
Max
Choice
Unit
Min
Default
1
0
2
0: V = ADC_I0
1: V = ADC_I1 (default)
2: V = ADC_I2
Mask
Name
Type
0x30000000h
ADC_I_WY_SELECT
Choice
Unit
Min
Max
Default
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.