TMC4671 Datasheet • IC Version V1.00 | Document Revision V1.04 • 2018-Dec-11
69 / 157
Address
Registername
Access
1: GND vs. INN
2: VDD/4
3: 3*VDD/4
4: INP vs. GND
5: VDD/2
6: VDD/4
7: 3*VDD/4
Mask
Name
Type
0x00F00000h
ADC_AENC_UX
Choice
Unit
Min
Max
7
Default
0
0
0: INP vs. INN
1: GND vs. INN
2: VDD/4
3: 3*VDD/4
4: INP vs. GND
5: VDD/2
6: VDD/4
7: 3*VDD/4
Mask
Name
Type
0x0F000000h
ADC_AENC_VN
Choice
Unit
Min
Max
7
Default
0
0
0: INP vs. INN
1: GND vs. INN
2: VDD/4
3: 3*VDD/4
4: INP vs. GND
5: VDD/2
6: VDD/4
7: 3*VDD/4
Mask
Name
Type
0xF0000000h
ADC_AENC_WY
Choice
Unit
Min
0
Max
7
Default
0
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com