TMC4671 Datasheet • IC Version V1.00 | Document Revision V1.04 • 2018-Dec-11
103 / 157
Address
Registername
4: PID_TORQUE_ERROR_SUM
5: PID_FLUX_ERROR_SUM
6: PID_VELOCITY_ERROR_SUM
7: PID_POSITION_ERROR_SUM
INTERIM_DATA
Access
0x6Eh
RW
Variant 0
Mask
Name
Type
Signed
Unit
0xFFFFFFFFh
PIDIN_TARGET_TORQUE
Min
Max
Default
0
-2147483648 2147483647
PIDIN target torque.
Variant 1
Mask
Name
Type
Signed
Unit
0xFFFFFFFFh
PIDIN_TARGET_FLUX
Max Default
Min
-2147483648 2147483647
PIDIN target flux.
Variant 2
0
Mask
Name
Type
Signed
Unit
0xFFFFFFFFh
PIDIN_TARGET_VELOCITY
Max Default
Min
-2147483648 2147483647
PIDIN target velocity.
Variant 3
0
Mask
Name
Type
Signed
Unit
0xFFFFFFFFh
PIDIN_TARGET_POSITION
Max Default
Min
-2147483648 2147483647
PIDIN target position.
Variant 4
0
Mask
Name
Type
Signed
Unit
0xFFFFFFFFh
PIDOUT_TARGET_TORQUE
Max Default
Min
-2147483648 2147483647
0
PIDOUT target torque.
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com