UCD9090  
SLVSA30A APRIL 2011REVISED AUGUST 2011  
www.ti.com  
UCD9090  
MONx  
INA196  
VOUT  
Vin+  
Vin-  
Rsense  
AVSS1  
GND  
V+  
3.3V  
Gain = 20V/V  
Figure 11. Current Monitoring Circuit Example using the INA196  
REMOTE TEMPERATURE MONITORING AND INTERNAL TEMPERATURE SENSOR  
The UCD9090 has support for internal and remote temperature sensing. The internal temperature sensor  
requires no calibration and can report the device temperature via the PMBus interface. The remote temperature  
sensor can report the remote temperature by using a configurable gain and offset for the type of sensor that is  
used in the application such as a linear temperature sensor (LTS) connected to the analog inputs.  
External circuitry must be used in order to convert the temperature to a voltage within the range of the UCD9090  
MONx input being used.  
If an input is configured as a temperature, the measurements are smoothed by a sliding average digital filter. The  
temperature for 1 rail is measured every 100ms. If the device is programmed to support 10 rails (independent of  
temperature not being monitored at all rails), then each rail's temperature will get measured every 1s. The  
temperature calculation is done with a sliding average using the last 16 measurements. The filter reduces the  
probability of false fault detections, and introduces a small delay to the temperature reading. The internal device  
temperature is measured using a silicon diode sensor with an accuracy of ±5°C and is also monitored using the  
ADC. Temperature monitoring begins immediately after reset and initialization.  
The device supports multiple PMBus commands related to temperature, including READ_TEMPERATURE_1,  
which reads the internal temperature; READ_TEMPERATURE_2, which reads external temperatures; and  
OT_FAULT_LIMIT and OT_WARN_LIMIT, which set the overtemperature fault and warning limit. The UCD90xxx  
Sequencer and System Health Controller PMBus Command Reference contains a detailed description of how  
temperature-fault responses are implemented using PMBus commands.  
TEMPERATURE_CAL_GAIN is a PMBus command that allows the scale factor of an external temperature  
sensor and any amplifiers or attenuators between the temperature sensor and the MON pin to be entered by the  
user in °C/V. TEMPERATURE_CAL_OFFSET is the temperature that results in 0 V at the MON pin. The  
combination of these PMBus commands allows temperature to be reported in degrees Celsius.  