 浏览型号TMS320C6416TZLZ7的Datasheet PDF文件第76页浏览型号TMS320C6416TZLZ7的Datasheet PDF文件第77页浏览型号TMS320C6416TZLZ7的Datasheet PDF文件第78页浏览型号TMS320C6416TZLZ7的Datasheet PDF文件第79页浏览型号TMS320C6416TZLZ7的Datasheet PDF文件第81页浏览型号TMS320C6416TZLZ7的Datasheet PDF文件第82页浏览型号TMS320C6416TZLZ7的Datasheet PDF文件第83页浏览型号TMS320C6416TZLZ7的Datasheet PDF文件第84页  
ꢀ ꢁ ꢂ ꢃ ꢄꢅ ꢆ ꢇ ꢈꢉ ꢈꢀꢊ ꢀꢁ ꢂꢃ ꢄ ꢅ ꢆꢇ ꢈ ꢉ ꢋꢀꢊ ꢀꢁ ꢂꢃ ꢄ ꢅ ꢆꢇ ꢈ ꢉ ꢇ ꢀ  
ꢌ ꢍ ꢎꢏ ꢐꢑꢒ ꢓꢍ ꢔ ꢀ ꢐꢍ ꢕ ꢍ ꢀꢖꢗ ꢂ ꢍ ꢕꢔ ꢖꢗ ꢒ ꢘꢓ ꢆꢏ ꢂꢂꢓ ꢘꢂ  
SPRS226H − NOVEMBER 2003 − REVISED AUGUST 2005  
INPUT AND OUTPUT CLOCKS  
†‡§  
timing requirements for CLKIN for -600 devices  
(see Figure 16)  
−600  
PLL MODE x20  
PLL MODE x12  
PLL MODE x6  
x1 (BYPASS)  
NO.  
UNIT  
MIN  
33.3  
0.4C  
0.4C  
MAX  
MIN  
20  
MAX  
MIN  
13.3  
0.4C  
0.4C  
MAX  
MIN  
0
MAX  
1
2
3
4
5
t
t
t
t
t
Cycle time, CLKIN  
40  
23.8  
23.8  
10  
ns  
ns  
ns  
ns  
ns  
c(CLKIN)  
w(CLKINH)  
w(CLKINL)  
t(CLKIN)  
Pulse duration, CLKIN high  
Pulse duration, CLKIN low  
Transition time, CLKIN  
Period jitter, CLKIN  
0.4C  
0.4C  
0.45C  
0.45C  
5
5
5
1
0.02C  
0.02C  
0.02C  
0.02C  
J(CLKIN)  
§
The reference points for the rise and fall transitions are measured at V MAX and V MIN.  
For more details on the PLL multiplier factors (x6, x12, x20), see the Clock PLL section of this data sheet.  
C = CLKIN cycle time in ns. For example, when CLKIN frequency is 50 MHz, use C = 20 ns.  
IL  
IH  
†‡§  
timing requirements for CLKIN for -720 devices  
(see Figure 16)  
−720  
PLL MODE x20  
PLL MODE x12  
PLL MODE x6  
x1 (BYPASS)  
NO.  
UNIT  
MIN  
27.7  
0.4C  
0.4C  
MAX  
MIN  
16.6  
0.4C  
0.4C  
MAX  
MIN  
13.3  
0.4C  
0.4C  
MAX  
MIN  
0
MAX  
1
2
3
4
5
t
t
t
t
t
Cycle time, CLKIN  
40  
23.8  
23.8  
10  
ns  
ns  
ns  
ns  
ns  
c(CLKIN)  
w(CLKINH)  
w(CLKINL)  
t(CLKIN)  
Pulse duration, CLKIN high  
Pulse duration, CLKIN low  
Transition time, CLKIN  
Period jitter, CLKIN  
0.45C  
0.45C  
5
5
5
1
0.02C  
0.02C  
0.02C  
0.02C  
J(CLKIN)  
§
The reference points for the rise and fall transitions are measured at V MAX and V MIN.  
For more details on the PLL multiplier factors (x6, x12, x20), see the Clock PLL section of this data sheet.  
C = CLKIN cycle time in ns. For example, when CLKIN frequency is 50 MHz, use C = 20 ns.  
IL  
IH  
80  
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443