TAS5711  
SLOS600 DECEMBER 2009  
www.ti.com  
BANK SWITCHING  
The TAS5711 uses an approach called bank switching together with automatic sample-rate detection. All  
processing features that must be changed for different sample rates are stored internally in three banks. The  
user can program which sample rates map to each bank. By default, bank 1 is used in 32kHz mode, bank 2 is  
used in 44.1/48 kHz mode, and bank 3 is used for all other rates. Combined with the clock-rate autodetection  
feature, bank switching allows the TAS5711 to detect automatically a change in the input sample rate and switch  
to the appropriate bank without any MCU intervention.  
An external controller configures bankable locations (0x29-0x36, 0x3A-0x3F, and 0x58-0x5F) for all three banks  
during the initialization sequence.  
If auto bank switching is enabled (register 0x50, bits 2:0) , then the TAS5711 automatically swaps the coefficients  
for subsequent sample rate changes, avoiding the need for any external controller intervention for a sample rate  
change.  
By default, bits 2:0 have the value 000; indicating that bank switching is disabled. In that state, updates to  
bankable locations take immediate effect. A write to register 0x50 with bits 2:0 being 001, 010, or 011 brings the  
system into the coefficient-bank-update state update bank1, update bank2, or update bank3, respectively. Any  
subsequent write to bankable locations updates the coefficient banks stored outside the DAP. After updating all  
the three banks, the system controller should issue a write to register 0x50 with bits 2:0 being 100; this changes  
the system state to automatic bank switching mode. In automatic bank switching mode, the TAS5711  
automatically swaps banks based on the sample rate.  
Command sequences for updating DAP coefficients can be summarized as follows:  
1. Bank switching disabled (default): DAP coefficient writes take immediate effect and are not  
influenced by subsequent sample rate changes.  
OR  
Bank switching enabled:  
(a) Update bank-1 mode: Write "001" to bits 2:0 of reg 0x50. Load the 32 kHz coefficients.  
(b) Update bank-2 mode: Write "010" to bits 2:0 of reg 0x50. Load the 48 kHz coefficients.  
(c) Update bank-3 mode: Write "011" to bits 2:0 of reg 0x50. Load the other coefficients.  
(d) Enable automatic bank switching by writing "100" to bits 2:0 of reg 0x50.  
26-Bit 3.23 Number Format  
All mixer gain coefficients are 26-bit coefficients using a 3.23 number format. Numbers formatted as 3.23  
numbers means that there are 3 bits to the left of the decimal point and 23 bits to the right of the decimal point.  
This is shown in Figure 54 .  
2–23 Bit  
2–5 Bit  
2–1 Bit  
20 Bit  
21 Bit  
Sign Bit  
S_xx.xxxx_xxxx_xxxx_xxxx_xxxx_xxx  
M0125-01  
Figure 54. 3.23 Format  