SN74LVC1G58
www.ti.com
SCES415N –NOVEMBER 2002–REVISED DECEMBER 2013
Electrical Characteristics
over recommended operating free-air temperature range (unless otherwise noted)
–40°C to 85°C
–40°C to 125°C
PARAMETER
TEST CONDITIONS
VCC
UNIT
MIN TYP(1)
0.79
1.11
1.5
MAX
1.16
1.56
1.87
2.74
3.33
0.62
0.87
1.19
1.9
MIN TYP(1)
0.79
1.11
1.5
MAX
1.16
1.56
1.87
2.74
3.33
0.62
0.87
1.19
1.9
1.65 V
2.3 V
VT+
Positive-going input
threshold voltage
3 V
V
4.5 V
2.16
2.61
0.35
0.58
0.84
1.41
1.87
0.3
2.16
2.61
0.35
0.58
0.84
1.41
1.87
0.3
5.5 V
1.65 V
2.3 V
VT–
Negative-going input
threshold voltage
3 V
V
V
4.5 V
5.5 V
2.29
0.62
0.8
2.29
0.62
0.8
1.65 V
2.3 V
0.4
0.4
ΔVT
3 V
0.53
0.71
0.71
0.87
1.04
1.11
0.53
0.71
0.71
0.87
1.04
1.11
Hysteresis (VT+ – VT–
)
4.5 V
5.5 V
IOH = –100 µA
1.65 V to 5.5 V
1.65 V
2.3 V
VCC – 0.1
VCC – 0.1
IOH = –4 mA
1.2
1.9
2.4
2.3
3.8
1.2
1.9
2.4
2.3
3.8
IOH = –8 mA
VOH
V
IOH = –16 mA
IOH = –24 mA
IOH = –32 mA
IOL = 100 µA
3 V
4.5 V
1.65 V to 5.5 V
1.65 V
0.1
0.45
0.3
0.1
0.45
0.3
IOL = 4 mA
IOL = 8 mA
2.3 V
VOL
V
IOL = 16 mA
0.4
0.45
0.55
0.58
±1
3 V
IOL = 24 mA
0.55
0.55
±1
IOL = 32 mA
4.5 V
0 to 5.5 V
0
II
VI = 5.5 V or GND
VI or VO = 5.5 V
VI = 5.5 V or GND, IO = 0
µA
µA
µA
Ioff
ICC
±10
10
±10
10
1.65 V to 5.5 V
One input at VCC – 0.6 V,
Other inputs at VCC or GND
ΔICC
3 V to 5.5 V
3.3 V
500
500
µA
pF
Ci
VI = VCC or GND
3.5
(1) All typical values are at VCC = 3.3 V, TA = 25°C.
Copyright © 2002–2013, Texas Instruments Incorporated
Submit Documentation Feedback
5
Product Folder Links: SN74LVC1G58