LM158, LM158A, LM258, LM258A
LM358, LM358A, LM358Y, LM2904, LM2904Q
DUAL OPERATIONAL AMPLIFIERS
SLOS068C – JUNE 1976 – REVISED JULY 1998
electrical characteristics at specified free-air temperature, V
= 5 V (unless otherwise noted)
CC
LM358A
†
‡
PARAMETER
UNIT
TEST CONDITIONS
T
A
§
TYP
MIN
MAX
25°C
2
3
5
V
V
= 5 V to 30 V,
CC
IC
V
IO
Input offset voltage
mV
= V
, V = 1.4 V
O
Full range
ICR(min)
Average temperature coefficient of
input offset voltage
α
Full range
7
2
20 µV/°C
VIO
25°C
30
nA
75
I
IO
Input offset current
V
O
= 1.4 V
Full range
Average temperature coefficient of
input offset current
α
Full range
10
300 pA/°C
IIO
25°C
–15
–100
nA
I
Input bias current
V
V
= 1.4 V
IB
O
Full range
–200
0 to
25°C
V
–1.5
CC
V
Common-mode input voltage range
= 30 V
V
V
ICR
CC
0 to
Full range
V
–2
CC
–1.5
R
≥ 2 kΩ
25°C
Full range
Full range
Full range
25°C
V
L
CC
26
V
V
High-level output voltage
Low-level output voltage
R
R
= 2 kΩ
OH
L
L
V
CC
= 30 V
≥ 10 kΩ
27
28
5
R
≤ 10 kΩ
20
mV
OL
L
25
15
65
100
Large-signal differential
voltage amplification
V
R
= 15 V, V = 1 V to 11 V,
O
= ≥ 2 kΩ
CC
A
V/mV
VD
Full range
25°C
L
CMRR
Common-mode rejection ratio
Supply-voltage rejection ratio
80
100
120
dB
dB
dB
k
25°C
65
SVR
/V
(∆V /∆V
DD IO
)
V
Crosstalk attenuation
f = 1 kHz to 20 kHz
25°C
O1 O2
†
‡
§
All characteristics are measured under open-loop conditions with zero common-mode input voltage, unless otherwise specified.
Full range is –55°C to 125°C for LM158A, –25°C to 85°C for LM258A, and 0°C to 70°C for LM358A.
All typical values are at T = 25°C.
A
8