LM158, LM158A, LM258, LM258A
LM358, LM358A, LM358Y, LM2904, LM2904Q
DUAL OPERATIONAL AMPLIFIERS
SLOS068C – JUNE 1976 – REVISED JULY 1998
electrical characteristics at specified free-air temperature, V
= 5 V (unless otherwise noted)
CC
LM158
LM258
LM358
†
‡
T
A
PARAMETER
UNIT
TEST CONDITIONS
§
TYP
§
TYP
MIN
MAX
MIN
MAX
V
V
V
= 5 V to MAX,
25°C
3
5
3
7
CC
IC
O
V
IO
Input offset voltage
mV
= V
,
ICR(min)
= 1.4 V
Full range
7
9
Average temperature
coefficient of
input offset voltage
α
Full range
7
2
7
2
µV/°C
nA
VIO
25°C
30
50
I
IO
Input offset current
V
= 1.4 V
= 1.4 V
O
Full range
100
150
Average temperature
coefficient of
input offset current
α
Full range
10
10
pA/°C
nA
IIO
25°C
–20 –150
–300
–20 –250
–500
I
IB
Input bias current
V
V
O
Full range
0 to
0 to
25°C
V
–1.5
V
–1.5
CC
0 to
–2
CC
0 to
–2
Common-mode
input voltage range
V
= 5 V to MAX
V
V
ICR
CC
Full range
V
V
CC
–1.5
CC
–1.5
R
R
≥ 2 kΩ
25°C
25°C
V
V
L
L
CC
CC
≥ 10 kΩ
High-level
output voltage
V
OH
OL
R
R
= 2 kΩ
Full range
Full range
26
27
26
27
L
L
V
CC
= MAX
≥ 10 kΩ
28
28
Low-level
output voltage
V
R
V
≤ 10 kΩ
Full range
5
20
5
20
mV
V/mV
dB
L
Large-signal
differential
voltage amplification
= 15 V,
= 1 V to 11 V,
= ≥ 2 kΩ
25°C
50
25
100
25
15
100
CC
A
V
O
VD
Full range
R
L
Common-mode
rejection ratio
V
V
= 5 V to MAX,
ICR(min)
CC
IC
CMRR
25°C
25°C
70
65
80
65
65
80
= V
Supply-voltage
rejection ratio
k
V
CC
= 5 V to MAX
100
100
dB
dB
SVR
(∆V /∆V
)
DD IO
V
/V
O1 O2
Crosstalk attenuation f = 1 kHz to 20 kHz
25°C
25°C
120
–30
120
–30
–20
–10
10
5
–20
–10
10
5
V
V
= 15 V, V = 1 V,
ID
= 0
CC
O
Full range
25°C
mA
I
O
Output current
20
20
V
V
= 15 V, V = –1 V,
ID
= 15 V
CC
O
Full range
25°C
V
ID
= –1 V,
V
O
= 200 mV
12
30
±40
0.7
1
12
30
±40
0.7
1
µA
Short-circuit
output current
V
at 5 V, GND at –5 V,
CC
I
I
25°C
±60
1.2
2
±60
1.2
2
mA
OS
V
O
= 0
V
O
= 2.5 V,
No load
Full range
Full range
Supply current
(two amplifiers)
mA
CC
V
= MAX, V = 0.5 V,
CC
O
No load
†
All characteristics are measured under open-loop conditions with zero common-mode input voltage, unless otherwise specified. MAX V
testing purposes is 26 V for LM 2904 and 30 V for others.
for
CC
‡
§
Full range is –55°C to 125°C for LM158, –25°C to 85°C for LM258, 0°C to 70°C for LM358, and –40°C to 125°C for LM2904 and LM2904Q.
All typical values are at T = 25°C.
A
5
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265