LM158, LM158A, LM258, LM258A
LM358, LM358A, LM358Y, LM2904, LM2904Q
DUAL OPERATIONAL AMPLIFIERS
SLOS068C – JUNE 1976 – REVISED JULY 1998
electrical characteristics at specified free-air temperature, V
= 5 V (unless otherwise noted)
CC
LM158A
LM258A
†
‡
T
A
PARAMETER
UNIT
TEST CONDITIONS
§
TYP
§
TYP
MIN
MAX
MIN
MAX
V
V
V
= 5 V to 30 V,
25°C
2
2
3
CC
IC
O
V
IO
Input offset voltage
mV
= V
,
ICR(min)
= 1.4 V
Full range
4
4
Average temperature
coefficient of
input offset voltage
α
Full range
7
2
15*
7
2
15 µV/°C
VIO
25°C
10
30
15
nA
30
I
IO
Input offset current
V
= 1.4 V
= 1.4 V
O
Full range
Average temperature
coefficient of
input offset current
α
Full range
10
200
10
200 pA/°C
IIO
25°C
–15
–50
–15
–80
nA
I
IB
Input bias current
V
V
O
Full range
–100
–100
0 to
0 to
25°C
V
–1.5
V
–1.5
CC
0 to
–2
CC
0 to
–2
Common-mode
input voltage range
V
= 30 V
V
V
ICR
CC
Full range
V
V
CC
–1.5
CC
–1.5
R
≥ 2 kΩ
25°C
V
V
L
CC
CC
High-level
output voltage
V
R
R
= 2 kΩ
Full range
26
27
26
27
OH
OL
L
L
V
CC
= 30 V
≥ 10 kΩ Full range
28
5
28
5
Low-level
output voltage
V
R
V
≤ 10 kΩ
Full range
20
20
mV
V/mV
dB
L
Large-signal
differential
voltage amplification
= 15 V,
= 1 V to 11 V,
= ≥ 2 kΩ
25°C
50
25
100
50
25
100
CC
A
V
O
VD
Full range
R
L
Common-mode
rejection ratio
CMRR
25°C
70
65
80
70
65
80
Supply-voltage
rejection ratio
k
25°C
25°C
100
120
100
120
dB
dB
SVR
(∆V /∆V
)
DD IO
V
/V
O1 O2
Crosstalk attenuation f = 1 kHz to 20 kHz
*On products compliant to MIL-PRF-38535, this parameter is not production tested.
†
‡
§
All characteristics are measured under open-loop conditions with zero common-mode input voltage, unless otherwise specified.
Full range is –55°C to 125°C for LM158A, –25°C to 85°C for LM258A, and 0°C to 70°C for LM358A.
All typical values are at T = 25°C.
A
7