INA282, INA283
INA284, INA285
INA286
SBOS485A –NOVEMBER 2009–REVISED JULY 2010
www.ti.com
V+ Referenced Output
This mode is set when both reference pins are connected to the positive supply. It is typically used when a
diagnostic scheme requires detection of the amplifier and the wiring before power is applied to the load (as
shown in Figure 35).
ISENSE
Supply
-14V to +80V
Load
V+
V+
+IN
-IN
Æ1
Æ2
Æ2
Æ1
Æ2
Æ2
Æ1
Æ1
OUT
ZerÆ-
Drift
Output
GAIN
PRODUCT
50V/V
INA282
INA286
INA283
INA284
INA285
33.3kW
33.3kW
100V/V
200V/V
500V/V
1000V/V
REF2
REF1
GND
Figure 35. V+ Referenced Output
16
Submit Documentation Feedback
Copyright © 2009–2010, Texas Instruments Incorporated
Product Folder Link(s): INA282 INA283 INA284 INA285 INA286