78P2342JAT
2-port E3/DS3/STS-1 LIU
with Jitter Attenuator
REGISTER DESCRIPTION (continued)
PORT-SPECIFIC REGISTERS
For PA[3:0] = N = 1-2 only. Accessing a register with port address greater than 2 constitutes an invalid
command, and the read/write operation will be ignored.
ADDRESS N-0: MODE CONTROL REGISTER
DFLT
BIT
NAME
TYPE
DESCRIPTION
VALUE
Transmitter Power-Down:
0 : Normal Operation
1 : Power-Down
7
PDTX
R/W
0
NOTE: Relevant only when the REGEN bit is set. Otherwise, LBOx pin
selection prevails.
Receiver Power-Down:
6
5
PDRX
LBO
R/W
R/W
0
1
0 : Normal Operation
1 : Power-Down
Transmitter Line Build-Out (DS3 and STS-1 only):
0 : ≥ 225ft of cable attached to the cross-connect
1 : < 225ft of cable attached to the cross-connect
NOTE: Relevant only when the REGEN bit is set. Otherwise, LBOx pin
selection prevails.
Local (Analog) Loopback Mode Selection:
[LLBKA LLBKB] = 00 : Normal operation
01 : Transmitter loopback
4
3
LLBKA
LLBKB
R/W
R/W
0
0
10 : Adjacent receiver input
11 : Adjacent transmitter loopback
NOTE: Relevant only when the REGEN bit is set. Otherwise, LPBKx pin
selection prevails.
Remote (Digital) Loopback Enable:
0 : Normal Operation
1 : Loops RCLK, RPOS, and RNEG back onto TCLK, TPOS, and TNEG
2
1
0
RLBK
MON
TXEN
R/W
R/W
R/W
0
0
1
NOTE: Relevant only when the REGEN bit is set. Otherwise, LPBKx pin
selection prevails.
Monitor Mode Enable: Used for reception of split-off signals that are flat
attenuated by at least 16dB but no more than 20dB.
0 : Disable
1 : Enable
Transmitter Output Enable:
0 : Transmit driver is disabled
1 : Normal Operation
NOTE: Relevant only when the REGEN bit is set. Otherwise, LBOx pin
selection prevails.
- 10 -