TCS3404, TCS3414  
DIGITAL COLOR SENSORS  
TAOS137A − APRIL 2011  
Timing Register (01h)  
The TIMING register controls the synchronization and integration time of the ADC channels. The Timing  
Register settings apply to all four ADC channels. The Timing Register defaults to 00h at power on.  
Table 5. Timing Register  
7
6
5
4
3
0
2
1
0
0
0
TIMING  
01h  
Resv SYNC_EDGE  
INTEG_MODE  
PARAM  
Reset Value:  
0
0
0
0
0
FIELD  
BITS  
DESCRIPTION  
Resv  
7
Reserved. Write as 0.  
Sync pin edge. If SYNC_EDGE is low, the falling edge of the sync pin is used to stop an integration  
cycle when INTEG_MODE is 11. If SYNC_EDGE is high, the rising edge of the sync pin is used to  
stop an integration cycle when INTEG_MODE is 11.  
SYNC_EDGE  
6
Selects preset integration time, manual integration (via serial bus), or external synchronization (SYNC  
IN) modes.  
FIELD VALUE  
MODE  
In this mode, the integrator is free-running and one of the three  
internally-generated Nominal Integration Times is selected for each conversion  
(see Integration Time table below).  
00  
Manually start/stop integration through serial bus using ADC_EN field in Con-  
trol Register.  
INTEG_MODE  
5:4  
01  
10  
Synchronize exactly one internally-timed integration cycle as specified in the  
NOMINAL INTEGRATION TIME beginning 2.4 μs after being initiated by the  
SYNC IN pin.  
Integrate over specified number of pulses on SYNC IN pin (See SYNC IN  
PULSE COUNT table below). Minimum width of sync pulse is 50 μs. SYNC  
IN must be low at least 3.6 μs.  
11  
Uses single, multipurpose bitmapped field to select one of three predefined integration times or set the  
number of SYNC IN pulses to count when the INTEG_MODE accumulate mode (11) is selected.  
NOTE: INTEG_MODE and TIME/COUNTER fields should be written before ADC_EN is asserted.  
FIELD VALUE  
0000  
NOMINAL INTEGRATION TIME  
12 ms  
0001  
100 ms  
400 ms  
0010  
FIELD VALUE  
0000  
SYNC IN PULSE COUNT  
PARAM  
3:0  
1
0001  
2
0010  
4
0011  
8
0100  
16  
32  
64  
128  
256  
0101  
0110  
0111  
1000  
Copyright E 2011, TAOS Inc.  
The LUMENOLOGY r Company  
r
r
16  
www.taosinc.com  