Technical
Specification
IQ18xxxSKxxx
Standards & Qualification Testing
Parameter
Notes & Conditions
STANDARDS COMPLIANCE
UL 60950-1: 2003
Basic Insulation
CAN/CSA-C22.2 No. 60950-1:2003
EN60950-1:2001
IEC 61000-4-2
ESD test, 8 kV - NP, 15 kV air - NP (Normal Performance)
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new
releases or download from the SynQor website.
Parameter
QUALIFICATION TESTING
Life Test
# Units Test Conditions
32
5
95% rated Vin and load, units at derating point, 1000 hours
Vibration
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis
100g minimum, 2 drops in x and y axis, 1 drop in z axis
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
5
10
5
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load
85 °C, 85% RH, 1000 hours, continuous Vin applied except 5 min/day
5
5
Solderability
15 pins MIL-STD-883, method 2003
70,000 feet (21 km), see Note
Altitude
2
Note: A conductive cooling design is generally needed for high altitude applications because of naturally poor convective cooling at rare atmospheres.
Product # IQ18xxxSKxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005462 Rev. C
05/27/10
Page 26