M24C16-125 M24C08-125 M24C04-125 M24C02-125
DC and AC parameters
Table 8.
Symbol
DC characteristics
Parameter
Test condition
(in addition to those in Table 5)
Min.
Max. Unit
Input leakage current (SCL,
SDA, E0, E1,and E2)
VIN = VSS or VCC, device in
Standby mode
ILI
-
-
-
-
-
-
2
2
µA
µA
mA
mA
µA
µA
V
SDA in Hi-Z, external voltage
applied on SDA: VSS or VCC
ILO
Output leakage current
VCC = 5 V, fC= 400 kHz
3
(rise/fall time < 50 ns)
ICC
Supply current
VCC = 2.5 V, fC = 400 kHz
(rise/fall time < 50 ns)
3
5
2
Device not selected(1), VIN = VSS
or VCC, VCC = 5 V
ICC1
Standby supply current
Device not selected(1), VIN = VSS
or VCC, VCC = 2.5 V
Input low voltage (SDA,
SCL, WC)
VIL
VIH
VOL
–0.45 0.3 VCC
0.7 VCC VCC+1
Input high voltage (SDA,
SCL, WC)
V
I
OL = 2.1 mA when VCC = 2.5 V or
IOL = 3 mA when VCC = 5.5 V
Output low voltage
-
0.4
V
1. The device is not selected after a power-up, after a read command (after the Stop condition), or after the
completion of the internal write cycle tW (tW is triggered by the correct decoding of a write command).
Doc ID 022564 Rev 1
21/30