DC and AC parameters
M24C16-125 M24C08-125 M24C04-125 M24C02-125
6
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristic tables that
follow are derived from tests performed under the measurement conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 5.
Symbol
Operating conditions
Parameter
Min.
Max.
Unit
VCC
Supply voltage
2.5
5.5
V
Ambient operating temperature
–40
125
°C
Table 6.
AC measurement conditions
Parameter
Symbol
Min.
Max.
Unit
Cbus
Load capacitance
100
pF
ns
V
SCL input rise/fall time, SDA input fall time
Input levels
-
50
0.2 VCC to 0.8 VCC
0.3 VCC to 0.7 VCC
Input and output timing reference levels
V
Figure 10. AC measurement I/O waveform
)NPUT VOLTAGE LEVELS
)NPUT AND OUTPUT
TIMING REFERENCE LEVELS
ꢊꢏꢃ 6
##
ꢊꢏꢂ 6
##
ꢊꢏꢆ 6
##
ꢊꢏꢄ 6
##
!)ꢊꢊꢃꢄꢈ#
Table 7.
Symbol
Input parameters
Parameter(1)
Test condition
Min.
Max.
Unit
CIN
CIN
Input capacitance (SDA)
Input capacitance (other pins)
WC input impedance
-
-
8
6
pF
pF
kΩ
kΩ
ZWCL
ZWCH
VIN < 0.3 V
15
500
70
-
WC input impedance
VIN > 0.7VCC
Pulse width ignored (input filter on
SCL and SDA)
tNS
Single glitch
-
100
ns
1. Characterized only.
20/30
Doc ID 022564 Rev 1