L6205
ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
Supply Voltage
Test conditions
Value
60
Unit
V
V
S
V
=
=
V
V
= V
S
SA
SB
V
OD
Differential Voltage between
V
V
= V = 60V;
60
V
SA
SB
S
VS , OUT1 , OUT2 , SENSE and
= V
= GND
A
A
A
A
SENSEA
SENSEB
VS , OUT1 , OUT2 , SENSE
B
B
B
B
V
Bootstrap Peak Voltage
Input and Enable Voltage Range
Voltage Range at pins SENSE
V
SA
=
V
SB
= V
V + 10
V
V
V
BOOT
S
S
V ,V
IN EN
-0.3 to +7
-1 to +4
V
SENSEA,
A
V
and SENSE
B
SENSEB
I
Pulsed Supply Current (for each
V pin), internally limited by the
S
V
t
=
V
= V ;
7.1
A
S(peak)
SA
SB
S
< 1ms
PULSE
overcurrent protection
I
RMS Supply Current (for each
V
SA
=
V
SB
= V
S
2.8
A
S
V pin)
S
T
, T
stg OP
Storage and Operating
Temperature Range
-40 to 150
°C
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
Supply Voltage
Test Conditions
MIN
MAX
Unit
V
V
S
V
=
=
V
V
= V
S
8
52
52
SA
SB
V
OD
Differential Voltage Between
V
V
= V ;
V
SA
SB
S
VS , OUT1 , OUT2 , SENSE and
= V
A
A
A
A
SENSEA
SENSEB
VS , OUT1 , OUT2 , SENSE
B
B
B
B
V
V
Voltage Range at pins SENSE
(pulsed t < t )
(DC)
-6
-1
6
1
V
V
SENSEA,
A
W
rr
and SENSE
SENSEB
B
I
RMS Output Current
2.8
+125
100
A
OUT
T
Operating Junction Temperature
Switching Frequency
-25
°C
j
f
KHz
sw
2/21