 浏览型号S71GL064A80BAI0F3的Datasheet PDF文件第36页浏览型号S71GL064A80BAI0F3的Datasheet PDF文件第37页浏览型号S71GL064A80BAI0F3的Datasheet PDF文件第38页浏览型号S71GL064A80BAI0F3的Datasheet PDF文件第39页浏览型号S71GL064A80BAI0F3的Datasheet PDF文件第41页浏览型号S71GL064A80BAI0F3的Datasheet PDF文件第42页浏览型号S71GL064A80BAI0F3的Datasheet PDF文件第43页浏览型号S71GL064A80BAI0F3的Datasheet PDF文件第44页  
A d v a n c e I n f o r m a t i o n  
Common Flash Memory Interface (CFI)  
The Common Flash Interface (CFI) specification outlines device and host system  
software interrogation handshake, which allows specific vendor-specified soft-  
ware algorithms to be used for entire families of devices. Software support can  
then be device-independent, JEDEC ID-independent, and forward- and back-  
ward-compatible for the specified flash device families. Flash vendors can  
standardize their existing interfaces for long-term compatibility.  
This device enters the CFI Query mode when the system writes the CFI Query  
command, 98h, to address 55h, any time the device is ready to read array data.  
The system can read CFI information at the addresses given in Table 18-Table 21.  
To terminate reading CFI data, the system must write the reset command.  
The system can also write the CFI query command when the device is in the au-  
toselect mode. The device enters the CFI query mode, and the system can read  
CFI data at the addresses given in Table 18-Table 21. The system must write the  
reset command to return the device to reading array data.  
For further information, please refer to the CFI Specification and CFI Publication  
100. Alternatively, contact your sales representative for copies of these  
documents.  
Table 18. CFI Query Identification String  
Addresses  
(x16)  
Data  
Description  
10h  
11h  
12h  
0051h  
0052h  
0059h  
Query Unique ASCII string “QRY”  
13h  
14h  
0002h  
0000h  
Primary OEM Command Set  
15h  
16h  
0040h  
0000h  
Address for Primary Extended Table  
17h  
18h  
0000h  
0000h  
Alternate OEM Command Set (00h = none exists)  
Address for Alternate OEM Extended Table (00h = none exists)  
19h  
1Ah  
0000h  
0000h  
40  
S71GL032A Based MCPs  
S71GL032A_00_A0 March 31, 2005  