D a t a S h e e t ( P r e l i m i n a r y )
13. Operating Ranges
Table 13.1 Operating Ranges
Description
Commerical
Industrial
Rating
Ambient Operating Temperature (T )
0°C to +70°C
–40°C to +85°C
2.7 V to 3.6 V
A
Positive Power Supply
Voltage Range
Note
Operating ranges define those limits between which functionality of the device is guaranteed.
14. DC Characteristics
This section summarizes the DC Characteristics of the device. Designers should check that the operating
conditions in their circuit match the measurement conditions specified in the Test Specifications in Table 15.1
on page 27, when relying on the quoted parameters.
Table 14.1 DC Characteristics (CMOS Compatible)
Parameter
Description
Test Conditions (See Note)
Min
Typ.
Max
Unit
VCC
Supply Voltage
2.7
3
3.6
V
SCK = 0.1 VCC/0.9VCC
33 MHz
9
mA
mA
ICC1
Active Read Current
VCC = 3.0V,
50 MHz
SCK = 0.1 VCC/0.9VCC
13
ICC2
ICC3
ICC4
ICC5
Active Page Program Current
Active WRSR Current
CS# = VCC
CS# = VCC
CS# = VCC
CS# = VCC
13.5
22
24
24
24
mA
mA
mA
mA
Active Sector Erase Current
Active Bulk Erase Current
V
CC = 3.0 V
ISB
IDP
Standby Current
20
50
5
µA
µA
CS# = VCC
VCC = 3.0 V
Deep Power Down Current
1.5
CS# = VCC
ILI
ILO
Input Leakage Current
Output Leakage Current
Input Low Voltage
VIN = GND to VCC
VIN = GND to VCC
1
1
µA
µA
V
VIL
–0.3
0.3 VCC
VCC + 0.5
0.4
VIH
VOL
VOH
Input High Voltage
0.7 VCC
V
Output Low Voltage
Output High Voltage
IOL = 1.6 mA, VCC = VCC min
IOH = –0.1 mA
V
VCC – 0.2
V
Note
Typical values are at T = 25°C and 3.0 V.
A
15. Test Conditions
Figure 15.1 AC Measurements I/O Waveform
0.8 VCC
Input Levels
0.2 VCC
0.7 VCC
0.5 VCC
0.3 VCC
Input and Output
26
S25FL040A
S25FL040A_00_B0 August 31, 2006