 浏览型号AM29LV640MH112RPCI的Datasheet PDF文件第26页浏览型号AM29LV640MH112RPCI的Datasheet PDF文件第27页浏览型号AM29LV640MH112RPCI的Datasheet PDF文件第28页浏览型号AM29LV640MH112RPCI的Datasheet PDF文件第29页浏览型号AM29LV640MH112RPCI的Datasheet PDF文件第31页浏览型号AM29LV640MH112RPCI的Datasheet PDF文件第32页浏览型号AM29LV640MH112RPCI的Datasheet PDF文件第33页浏览型号AM29LV640MH112RPCI的Datasheet PDF文件第34页  
D A T A S H E E T  
Write “Write to Buffer”  
command and  
Sector Address  
Part of “Write to Buffer”  
Command Sequence  
Write number of addresses  
to program minus 1(WC)  
and Sector Address  
Write first address/data  
Yes  
WC = 0 ?  
No  
Write to a different  
sector address  
Abort Write to  
Buffer Operation?  
Yes  
Write to buffer ABORTED.  
Must write “Write-to-buffer  
Abort Reset” command  
sequence to return  
No  
(Note 1)  
Write next address/data pair  
to read mode.  
WC = WC - 1  
Write program buffer to  
flash sector address  
Notes:  
1. When Sector Address is specified, any address in  
the selected sector is acceptable. However, when  
loading Write-Buffer address locations with data, all  
addresses must fall within the selected Write-Buffer  
Page.  
Read DQ7 - DQ0 at  
Last Loaded Address  
2. DQ7 may change simultaneously with DQ5.  
Therefore, DQ7 should be verified.  
3. If this flowchart location was reached because  
DQ5= “1”, then the device FAILED. If this flowchart  
location was reached because DQ1= “1”, then the  
Write to Buffer operation was ABORTED. In either  
case, the proper reset command must be written  
before the device can begin another operation. If  
DQ1=1, write the  
Yes  
DQ7 = Data?  
No  
No  
Write-Buffer-Programming-Abort-Reset  
command. if DQ5=1, write the Reset command.  
No  
DQ1 = 1?  
Yes  
DQ5 = 1?  
Yes  
4. See Table 11 for command sequences required for  
write buffer programming.  
Read DQ7 - DQ0 with  
address = Last Loaded  
Address  
Yes  
(Note 2)  
DQ7 = Data?  
No  
(Note 3)  
FAIL or ABORT  
PASS  
Figure 4. Write Buffer Programming Operation  
28  
Am29LV640MH/L  
December 14, 2005  