D A T A S H E E T
ABSOLUTE MAXIMUM RATINGS
Exposure of the device to absolute maximum rating
conditions for extended periods may affect device reliability.
Storage Temperature
Plastic Packages . . . . . . . . . . . . . . . –65°C to +150°C
Ambient Temperature
with Power Applied. . . . . . . . . . . . . . –65°C to +125°C
20 ns
20 ns
Voltage with Respect to Ground
+0.8 V
V
CC (Note 1). . . . . . . . . . . . . . . . .–0.5 V to +4.0 V
–0.5 V
–2.0 V
A9, OE#, and
RESET# (Note 2). . . . . . . . . . . .–0.5 V to +12.5 V
All other pins (Note 1) . . . . . .–0.5 V to VCC+0.5 V
Output Short Circuit Current (Note 3) . . . . . . 200 mA
20 ns
Notes:
Figure 7. Maximum Negative
Overshoot Waveform
1. Minimum DC voltage on input or I/O pins is –0.5 V.
During voltage transitions, input or I/O pins may
overshoot VSS to –2.0 V for periods of up to 20 ns. See
Figure 7. Maximum DC voltage on input or I/O pins is
V
CC +0.5 V. During voltage transitions, input or I/O pins
20 ns
may overshoot to VCC +2.0 V for periods up to 20 ns. See
Figure 8.
VCC
2. Minimum DC input voltage on pins A9, OE#, and RESET#
is –0.5 V. During voltage transitions, A9, OE#, and RESET#
may overshoot VSS to –2.0 V for periods of up to 20 ns. See
Figure 7. Maximum DC input voltage on pin A9 is +12.5 V
which may overshoot to 14.0 V for periods up to 20 ns.
+2.0 V
VCC
+0.5 V
2.0 V
3. No more than one output may be shorted to ground at a
time. Duration of the short circuit should not be greater than
one second.
20 ns
20 ns
Figure 8. Maximum Positive
Overshoot Waveform
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device. This
is a stress rating only; functional operation of the device at
these or any other conditions above those indicated in the
operational sections of this data sheet is not implied.
OPERATING RANGES
Commercial (C) Devices
Ambient Temperature (TA) . . . . . . . . . . . 0°C to +70°C
Industrial (I) Devices
Ambient Temperature (TA) . . . . . . . . . –40°C to +85°C
Extended (E) Devices
Ambient Temperature (TA) . . . . . . . . –55°C to +125°C
V
CC Supply Voltages
VCC for regulated voltage range . . . . .+3.0 V to +3.6 V
CC for full voltage range . . . . . . . . . .+2.7 V to +3.6 V
Operating ranges define those limits between which the functionality of the device is guaranteed.
V
24
Am29LV400B
21523D4 December 4, 2006