CXD1968AR  
SYR_TRACKCLIPLEVEL  
Read/Write  
RESET: 0x22  
Default R/W  
Offset Address: 0x4A  
Bit  
Name  
Description  
7:6 Reserved  
00  
R/W  
Sets the threshold of useful equalization i.e. the level of any  
echo path that must be equalized relative to the frequency  
5:3 FTRACKCLIPLEVEL domain noise floor. The default value of 4 relates to an echo  
level at approximately –21dB of the main path.  
100  
R/W  
(0: Lowest level, 7: Highest level).  
Sets the threshold of useful equalization i.e. the level of any  
echo path that must be equalized relative to the time  
2:0 TTRACKCLIPLEVEL domain noise floor. The default value of 2 relates to an echo  
level at approximately –21dB of the main path.  
010  
R/W  
(0: Lowest level, 7: Highest level).  
SYR_DOPPLER  
Read/Write  
RESET: 0x14  
Default R/W  
Offset Address: 0x4B  
Bit  
Name  
Description  
7:6 Reserved  
00  
R/W  
Sets the number of tracking periods during which the  
enhanced symbol tracker must observe a persistent  
change in the channel profile before reacting to it.  
Increasing this register value prevents the symbol tracker  
reacting to spurious and/or transient events.  
5:3 DOPPLERHYSTER  
010  
R/W  
Sets the threshold level (FALSEALIASLEVEL) for valid  
path energy detection in the channel transfer function used  
for symbol tracking.  
2:0 FALSEALIASLEVEL  
100  
R/W  
SYR_MISC1  
Read/Write  
Description  
RESET: 0xFE  
Default R/W  
Offset Address: 0x4C  
Bit  
Name  
Sets threshold that must be satisfied to provide  
enough certainty to an auto-guard/mode detection  
outcome of 2K, 1/32.  
Lower to tighten the decision and increase to loosen  
the decision.  
7:5 ZEROGUARDBACKOFF  
4:1 AUTOGUARDBACKOFF  
111  
R/W  
Sets the threshold that must be satisfied to provide  
enough certainty on the auto-guard/mode detection  
outcome.  
Lower to tighten the decision and increase to loosen  
the decision.  
1111  
0
R/W  
R/W  
Allows single path channels to be treated as long  
post-cursive or pre-cursive channels.  
0
ONEPATH SLOPE ENABLE  