High Performance Two Port 10/100 Managed Ethernet Switch with 32-Bit Non-PCI CPU Interface  
Datasheet  
Table 4.2 Soft-Strap Configuration Strap Definitions (continued)  
DESCRIPTION  
PIN / DEFAULT  
VALUE  
STRAP NAME  
manual_FC_strap_2  
Port 2 Manual Flow Control Enable Strap: Configures the  
default value of the Port 2 Full-Duplex Manual Flow Control  
Select (MANUAL_FC_2) bit in the Port 2 Manual Flow  
Control Register (MANUAL_FC_2). When configured low,  
flow control is determined by auto-negotiation (if enabled),  
and symmetric PAUSE is advertised (bit 10 of the Port x  
PHY Auto-Negotiation Advertisement Register  
0b  
(PHY_AN_ADV_x) is set).  
When configured high, flow control is determined by the  
Port 2 Full-Duplex Transmit Flow Control Enable  
(TX_FC_2) and Port 2 Full-Duplex Receive Flow Control  
Enable (RX_FC_2) bits, and symmetric PAUSE is not  
advertised (bit 10 of the Port x PHY Auto-Negotiation  
Advertisement Register (PHY_AN_ADV_x) is cleared).  
BP_EN_strap_mii  
FD_FC_strap_mii  
Port 0(Host MAC) Backpressure Enable Strap:  
Configures the default value for the Port 0 Backpressure  
Enable (BP_EN_MII) bit of the Port 0(Host MAC) Manual  
Flow Control Register (MANUAL_FC_MII). When  
configured low, backpressure is disabled. When configured  
high, backpressure is enabled.  
1b  
1b  
Port 0(Host MAC) Full-Duplex Flow Control Enable  
Strap: Configures the default of the TX_FC_MII and  
RX_FC_MII bits in the Port 0(Host MAC) Manual Flow  
Control Register (MANUAL_FC_MII) which are used when  
manual full-duplex flow control is selected. When  
configured low, flow control is disabled on RX/TX. When  
configured high, flow control is enabled on RX/TX.  
manual_FC_strap_mii  
Port 0(Host MAC) Manual Flow Control Enable Strap:  
Configures the default value of the MANUAL_FC_MII bit in  
the Port 0(Host MAC) Manual Flow Control Register  
(MANUAL_FC_MII). When configured low, flow control is  
determined by Virtual Auto-Negotiation (if enabled). When  
configured high, flow control is determined by TX_FC_MII  
and RX_FC_MII bits in the Port 0(Host MAC) Manual Flow  
Control Register (MANUAL_FC_MII).  
0b  
SQE_test_disable_strap_mii  
SQE Heartbeat Disable Strap: Configures the Signal  
Quality Error (Heartbeat) test function by controlling the  
default value of the SQEOFF (bit 0) of the Virtual PHY  
Special Control/Status Register  
0b  
(VPHY_SPECIAL_CONTROL_STATUS). When configured  
low, SQEOFF defaults to 0 and SQE test is enabled. When  
configured high, SQEOFF defaults to 1 and SQE test is  
disabled.  
4.2.4.2  
Hard-Straps  
Hard-straps are latched upon Power-On Reset (POR) or pin reset (nRST) only. Unlike soft-straps,  
hard-straps always have an associated pin and cannot be overridden by the EEPROM Loader. These  
straps are used as either direct configuration values or as register defaults. Table 4.3 provides a list of  
all hard-straps and their associated pin. These straps, along with their pin assignments are also fully  
defined in Chapter 3, "Pin Description and Configuration," on page 26.  
SMSC LAN9312  
Revision 1.2 (04-08-08)  
DATA4S5HEET  
 复制成功!