to avoid conflict with standard ISA devices. The
port is equivalent to a generic parallel port
interface and may be operated in that mode.
The port registers vary depending on the mode
field in the ecr. The table below lists these
dependencies. Operation of the devices in
modes other that those specified is undefined.
Register Definitions
The register definitions are based on the
standard IBM addresses for LPT. All of the
standard printer ports are supported.
additional registers attach to an upper bit
decode of the standard LPT port definition
The
Table 42 - ECP Register Definitions
ADDRESS (Note 1) ECP MODES
NAME
FUNCTION
Data Register
data
+000h R/W
+000h R/W
+001h R/W
+002h R/W
+400h R/W
+400h R/W
+400h R/W
+400h R
000-001
011
All
ecpAFifo
dsr
ECP FIFO (Address)
Status Register
dcr
All
Control Register
cFifo
ecpDFifo
tFifo
010
011
110
111
111
All
Parallel Port Data FIFO
ECP FIFO (DATA)
Test FIFO
cnfgA
cnfgB
ecr
Configuration Register A
Configuration Register B
Extended Control Register
+401h R/W
+402h R/W
Note 1: These addresses are added to the parallel port base address as selected by configuration
register or jumpers.
Note 2: All addresses are qualified with AEN. Refer to the AEN pin definition.
Table 43 - Mode Descriptions
MODE
000
001
010
011
100
101
110
111
DESCRIPTION*
SPP mode
PS/2 Parallel Port mde
Parallel Port Data FIFO mode
ECP Parallel Port mode
EPP mode (If this option is enabled in the configuration registers)
(Reserved)
Test mode
Configuration mode
*Refer to ECR Register Description