Fan Control Device with Hardware Monitoring and Acoustic Noise Reduction Features  
Datasheet  
Write Byte  
The Write Byte protocol is used to write data to the registers. The data will only be written if the protocol  
shown in Table 4.2 is performed correctly. Only one byte is transferred at time for a Write Byte protocol.  
Table 4.2 SMBus Write Byte Protocol  
FIELD  
Bits  
START  
SLAVE ADDR  
WR  
ACK  
REG. ADDR  
ACK  
REG. DATA  
ACK  
STOP  
1
7
1
1
8
1
8
1
1
Read Byte  
The Read Byte protocol is used to read data from the registers. The data will only be read if the  
protocol shown in Table 4.3 is performed correctly. Only one byte is transferred at time for a Read Byte  
protocol.  
Table 4.3 SMBus Read Byte Protocol  
SLAVE  
ADDR  
REG.  
SLAVE  
ADDR  
REG.  
FIELD:  
Bits:  
START  
WR  
ACK  
ADDR  
ACK  
START  
RD  
ACK  
DATA  
NACK  
STOP  
1
7
1
1
8
1
1
7
1
1
8
1
1
4.4  
Invalid Protocol Response Behavior  
Registers that are accessed with an invalid protocol will not be updated. A register will only be updated  
following a valid protocol. The only valid protocols are the Write Byte and Read Byte protocols, which  
are described above.  
The EMC6D102 device responds to three SMBus slave addresses:  
1. The SMBus slave address that supports the valid protocols defined in the previous sections is  
determined by the level on the Address Select and Address Enable pins as shown in Section 4.1,  
"Slave Address," on page 13.  
2. SMBus Alert Response (0001 100). The SMBus will only respond to the SMBus Alert Response  
Address if the SMBus Alert Response interrupt was generated to request a response from the Host.  
The SMBus Alert Response is defined in Section 4.10, "SMBus Alert Response Address," on  
page 16.  
Attempting to communicate with the Hardware Monitor Block over SMBus with an invalid slave  
address, or invalid protocol will result in no response, and the SMBus Slave Interface will return to the  
idle state.  
The only valid registers that are accessible by the SMBus slave address are the registers defined in  
the Registers Section. See Section 4.4.1, "Undefined Registers" for response to undefined registers.  
4.4.1  
Undefined Registers  
Reads to undefined registers return 00h. Writes to undefined registers have no effect and return no  
error.  
4.5  
General Call Address Response  
The EMC6D102 will not respond to a general call address of 0000_000.  
SMSC EMC6D102  
Revision 0.4 (04-05-05)  
DATA1S5HEET