Fan Control Device with Hardware Monitoring and Acoustic Noise Reduction Features  
Datasheet  
Chapter 4 SMBus Interface  
The host processor communicates with the Fan Monitoring device through a series of read/write  
registers via the SMBus interface. SMBus is a serial communication protocol between a computer host  
and its peripheral devices.  
4.1  
Slave Address  
The default Slave Address is 0101110b. If this address is desired, the designer should not ground the  
Address Enable# pin and should not apply a strapping resistor to the Address Select pin.  
If multiple devices are implemented in a system or another SMBus device requires address 0101110b,  
TACH4 and PWM3 must be disabled. In this case, addressing is implemented as follows:  
The board designer will apply a 10Kpull-down resistor to ground on the Address Enable# pin. Upon  
power up, the EMC6D102 device will be placed into Address Enable mode and assign itself an SMBus  
address according to the Address Select input. The device will latch the address during the first valid  
SMBus transaction in which the first five bits of the targeted address match those of the EMC6D102  
address. This feature eliminates the possibility of a glitch on the SMBus interfering with address  
selection.  
Table 4.1 SMBus Slave Address Options  
ADDRESS  
ADDRESS  
ENABLE#  
SELECT  
BOARD IMPLEMENTATION  
SMBUS ADDRESS [7:1]  
1
X
Address Enable# pulled to VCC through resistor  
0101 110b  
(default)  
Note:  
Resistor value will be dependent on PWM  
circuit implemented.  
0
0
0
1
Address Enable# pulled to ground through 10kΩ  
0101 100b  
0101 101b  
resistor  
Address Select Pulled to ground through a 10kΩ  
resistor  
Address Enable# pulled to ground through 10kΩ  
resistor  
Address Select pulled to VCC through a 10kΩ  
resistor  
In this way, there can be up to three EMC6D102 devices on the SMBus at any time. Multiple  
EMC6D102 devices can be used to monitor additional processors and temperature zones.  