Environmental Monitoring and Control Device
Datasheet
Bit[5]
Indicates a premature stop was detected.
Bit[6]
Indicates an error was detected during the SMBus Receive Byte Protocol Response to an ARA.
Bit[7]
Reserved.
8.28 Register 7Bh: Test Digital Value Register
BIT 7
(MSB)
BIT 0
(LSB)
REGISTER
ADDRESS
READ/
WRITE
REGISTER
NAME
DEFAULT
VALUE
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
Test Digital
Value
7Bh
R/W
7
6
5
4
3
2
1
0
00h
These registers become read only when the Lock bit is set. Any further attempts to write to these registers
shall have no effect.
8.29 Register 7Ch: Special Function Register
BIT 7
(MSB)
BIT 0
(LSB)
REGISTER READ/
ADDRESS WRITE
REGISTER
NAME
DEFAULT
VALUE
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
7Ch
R/W
Special
D2EN D1EN
AVG OFFCFG VOLTEN INTEN MONMD LPMD
E0h
Function
This register becomes read only when the Lock bit is set. Any further attempts to write to this register shall
have no effect.
This register contains the following bits:
Bit[0]
Low-Power Mode Select
0= Sleep Mode (default)
1= Shutdown Mode
Bit[1]
Monitoring Mode Select
0= Continuous Monitor Mode (default)
1= Cycle Monitor Mode
Bit[2]
nINT Enable (EMC6D100 only)
SMSC EMC6D100/EMC6D101
Page 61
Rev. 09-09-04
DATASHEET