Environmental Monitoring and Control Device  
2. 16 measurements are averaged for the remote diode temperature reading and a single measurement is tDaakteasnhfeoert  
all voltage and the internal temperature reading (i.e., no averaging). This is a power saving option. This is the  
default operation.  
For option 1, the block performs a total of (2 x 128) + (1 x 8) + (8 x 8) = 328 conversions.  
Option 2 reduces the number of conversions to (2 x 16) + (1 x 1) + (8 x 1) = 41.  
Each temperature conversion takes 2 ms approx. and each voltage conversion takes 1.5 ms approx.  
The total time for option 1 (328 conversions) is (2x128x2) + (1x8x2) + (8x8x1.5) = 624 ms.  
The total time for option 2 (41 conversions) is (2x16x2) + (1x1x2) + (8x1x1.5) = 78 ms.  
6.3.1 CONTINUOUS MONITORING MODE  
In the continuous monitoring mode, the sampling and conversion process is performed continuously for  
each voltage and temperature reading after the Start bit is set high. The time for each voltage and  
temperature reading is shown above for each measurement option.  
The continuous monitoring function is started by doing a write to the Ready/Lock/Start Register, setting the  
Start bit (Bit 0) high. The part then performs a “round robin” sampling of the inputs, in the order shown  
below (corresponding to locations in the RAM). Sampling of all values occurs in 624 ms (or 78 ms - see  
above).  
SAMPLING ORDER  
REGISTER  
Remote Diode Temp Reading 1  
Ambient Temperature reading  
VCC reading  
1
2
3
4
5
+12V reading  
+5V reading  
6
7
+3.3V reading  
+2.5V reading  
8
9
10  
11  
Vccp (processor) reading  
Remote Diode Temp Reading 2  
+1.8V reading  
+1.5V reading  
When the continuous monitoring function is started, it cycles through each measurement in sequence, and  
it continuously loops through the sequence approximately once every 624 ms (or 78 ms – see above).  
Each measured value is compared to values stored in the Limit registers. When the measured value  
violates (or is equal to) the programmed limit the Hardware Monitor Block will set a corresponding status  
bit in the Interrupt Status Registers.  
If auto fan option is selected, the hardware will adjust the operation of the fans accordingly. See section  
7.4.2 Auto Fan Control Operating Mode on page 31.  
The results of the sampling and conversions can be found in the Reading Registers and are available at  
any time.  
6.3.2 CYCLE MONITORING MODE  
In cycle monitoring mode, the part completes all sampling and conversions, then waits to repeat the  
process. It repeats the sampling and conversion process every second (1.4 sec max). The sampling and  
SMSC EMC6D100/EMC6D101  
Page 22  
Rev. 09-09-04  
DATASHEET  