Environmental Monitoring and Control Device  
Datasheet  
Table 5.2 - SMBus Read Byte Protocol  
SLAVE  
ADDR  
REG.  
SLAVE  
ADDR  
REG.  
FIELD: START  
BITS:  
WR  
ACK  
ACK START  
RD ACK  
NACK STOP  
ADDR  
DATA  
1
7
1
1
8
1
1
7
1
1
8
1
1
Send Byte  
The Send Byte protocol is used to set the Internal Address Register to the correct register in the EMC  
Register Block. No data is transferred for a Send Byte protocol. The Send Byte can be followed by the  
Receive Byte protocol described below in order to read data from the register. The send byte protocol  
cannot be used to write data - if data is to be written to a register then the write byte protocol must be used  
as described in subsection above. The send byte protocol is shown in the table below.  
Table 5.3 - SMBus Send Byte Protocol  
SLAVE  
ADDR  
REG.  
FIELD: START  
BITS:  
WR ACK  
ACK STOP  
ADDR  
1
7
1
1
8
1
1
Receive Byte  
The Receive Byte protocol is used to read data from the registers when the register address is known to  
be at the desired address (using the Internal Address Register). This is used when the register address  
has been written to the desired address using the Send Byte protocol. This can be used for successive  
reads of the same register. The data will only be read if the protocol shown in Table 5.4 is performed  
correctly. Only one byte is transferred at time for a Receive Byte protocol.  
Table 5.4 - SMBus Receive Byte Protocol  
SLAVE  
FIELD: START  
BITS:  
RD ACK REG. DATA  
NACK  
STOP  
ADDR  
1
7
1
1
8
1
1
5.4  
Invalid Protocol Response Behavior  
Registers that are accessed with an invalid protocol will not be updated. A register will only be updated  
following a valid protocol. The only valid protocols are the Write Byte, Read Byte, Send Byte, and Receive  
Byte protocols, which are described above.  
The EMC6D100/EMC6D101 device responds to three SMBus slave addresses:  
1) The SMBus slave address that supports the valid protocols defined in the previous sections  
is determined by the level on the Address Select and Address Enable pins as shown in  
section 5.1 Slave Address on page 16.  
2) SMBus General Call Address (0001 100). The SMBus will only respond to the General Call  
Address if the SMBus Alert Response interrupt was generated to request a response from  
the Host. The SMBus Allert Response is defined in section 5.10 SMBus Alert Response  
Address on page 19.  
Attempting to communicate with the EMC device over the SMBus with an invalid slave address, or invalid  
protocol will result in no response, and the SMBus Slave Interface will return to the idle state.  
SMSC EMC6D100/EMC6D101  
Page 18  
Rev. 09-09-04  
DATASHEET  