 浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第32页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第33页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第34页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第35页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第37页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第38页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第39页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第40页  
Dual RPM-Based PWM Fan Controller  
Datasheet  
5.14  
Fan Minimum Drive Registers  
Table 5.24 Minimum Fan Drive Registers  
ADDR  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Fan 1  
Minimum  
Drive  
66h  
(40%)  
38h  
48h  
R/W  
128  
64  
32  
16  
8
4
2
1
Fan 2  
Minimum  
Drive  
66h  
(40%)  
R/W  
128  
64  
32  
16  
8
4
2
1
The Fan Minimum Drive registers store the minimum drive setting for each RPM-based Fan Speed  
Control Algorithm. The RPM-based Fan Speed Control Algorithm will not drive the fan at a level lower  
than the minimum drive unless the target Fan Speed is set at FFh (see Section 5.17).  
During normal operation, if the fan stops for any reason (including low drive), the RPM-based Fan  
Speed Control Algorithm will attempt to restart the fan. Setting the Fan Minimum Drive Register to a  
setting that will maintain fan operation is a useful way to avoid potential fan oscillations as the control  
circuitry attempts to drive it at a level that cannot support fan operation.  
The Fan Minimum Drive Registers are software locked.  
5.15  
Valid TACH Count Registers  
Table 5.25 Valid TACH Count Registers  
ADDR  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Valid TACH  
Count 1  
39h  
R/W  
4096  
2048  
1024  
512  
256  
128  
64  
32  
F5h  
Valid TACH  
Count 2  
49h  
R/W  
4096  
2048  
1024  
512  
256  
128  
64  
32  
F5h  
The Valid TACH Count registers store the maximum TACH Reading Register value to indicate that  
each fan is spinning properly. The value is referenced at the end of the Spin Up Routine to determine  
if the fan has started operating and decide if the device needs to retry. See Equation [2] in Section 5.18  
for translating the count to an RPM.  
If the TACH Reading Register value exceeds the Valid TACH Count Register (indicating that the Fan  
RPM is below the threshold set by this count), then a stalled fan is detected. In this condition, the  
algorithm will automatically begin its Spin Up Routine.  
If a TACH Target setting is set above the Valid TACH Count setting, then that setting will be ignored  
and the algorithm will use the current fan drive setting.  
The Valid TACH Count registers are software locked.  
Revision 1.1 (10-12-09)  
SMSC EMC2302  
DATA3S6HEET