 浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第30页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第31页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第32页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第33页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第35页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第36页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第37页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第38页  
Dual RPM-Based PWM Fan Controller  
Datasheet  
Table 5.20 DRIVE_FAIL_CNT[1:0] Bit Decode  
DRIVE_FAIL_CNTX[1:0]  
1
0
NUMBER OF UPDATE PERIODS  
0
0
Disabled - the Drive Fail detection circuitry is disabled (default)  
16 - the Drive Fail detection circuitry will count for 16 update  
periods  
0
1
1
1
0
1
32 - the Drive Fail detection circuitry will count for 32 update  
periods  
64 - the Drive Fail detection circuitry will count for 64 update  
periods  
Bit 5 - NOKICKx - Determines if the Spin Up Routine will drive the fan to 100% duty cycle for 1/4 of  
the programmed spin up time before driving it at the programmed level.  
„
‘0’ (default) - The Spin Up Routine will drive the fan driver to 100% for 1/4 of the programmed spin  
up time before reverting to the programmed spin level.  
„
‘1’ - The Spin Up Routine will not drive the fan driver to 100%. It will set the drive at the  
programmed spin level for the entire duration of the programmed spin up time.  
Bits 4 - 2 - SPIN_LVLx[2:0] - Determines the final drive level that is used by the Spin Up Routine as  
shown in Table 5.21.  
Table 5.21 Spin Level  
SPIN_LVLX[2:0]  
2
1
0
SPIN UP DRIVE LEVEL  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
30%  
35%  
40%  
45%  
50%  
55%  
60% (default)  
65%  
Bit 1 -0 - SPINUP_TIMEx[1:0] - determines the maximum Spin Time that the Spin Up Routine will run  
for (see Section 4.6). If a valid tachometer measurement is not detected before the Spin Time has  
elapsed, then an interrupt will be generated. When the RPM-based Fan Speed Control Algorithm is  
active, the fan driver will attempt to re-start the fan immediately after the end of the last spin up attempt.  
The Spin Time is set as shown in Table 5.22.  
Revision 1.1 (10-12-09)  
SMSC EMC2302  
DATA3S4HEET