 浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第28页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第29页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第30页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第31页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第33页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第34页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第35页浏览型号EMC2302-1-AIZL-TR的Datasheet PDF文件第36页  
Dual RPM-Based PWM Fan Controller  
Datasheet  
Bit 6 - EN_RRCx - Enables ramp rate control when the corresponding fan driver is operated in the  
Direct Setting Mode.  
„
‘0’ (default) - Ramp rate control is disabled. When the fan driver is operating in Direct Setting mode,  
the fan setting will instantly transition to the next programmed setting.  
„
‘1’ - Ramp rate control is enabled. When the fan driver is operating in Direct Setting mode, the fan  
drive setting will follow the ramp rate controls as determined by the Fan Step and Update Time  
settings. The maximum fan drive setting step is capped at the Fan Step setting and is updated  
based on the Update Time as given by Table 5.13.  
Bit 5 - GLITCH_ENx - Disables the low pass glitch filter that removes high frequency noise injected  
on the TACHx pin.  
„
„
‘0’ - The glitch filter is disabled.  
‘1’ (default) - The glitch filter is enabled.  
Bits 4 - 3 - DER_OPTx[1:0] - Control some of the advanced options that affect the derivative portion  
of the RPM-based Fan Speed Control Algorithm as shown in Table 5.15.  
Table 5.15 Derivative Options  
DER_OPTX[1:0]  
1
0
OPERATION  
0
0
No derivative options used  
Basic derivative. The derivative of the error from  
the current drive setting and the target is added  
to the iterative Fan Drive Register setting (in  
addition to proportional and integral terms)  
(default)  
0
1
Step derivative. The derivative of the error from  
the current drive setting and the target is added  
to the iterative Fan Drive Register setting and is  
not capped by the Fan Step Register.  
1
1
0
1
Both the basic derivative and the step derivative  
are used effectively causing the derivative term to  
have double the effect of the derivative term.  
Bit 2 - 1 - ERR_RNGx[1:0] - Control some of the advanced options that affect the error window. When  
the measured fan speed is within the programmed error window around the target speed, then the fan  
drive setting is not updated. The algorithm will continue to monitor the fan speed and calculate  
necessary drive setting changes based on the error; however, these changes are ignored.  
Table 5.16 Error Range Options  
ERR_RNGX[1:0]  
1
0
OPERATION  
0
0
1
1
0
1
0
1
0 RPM (default)  
50 RPM  
100 RPM  
200 RPM  
Revision 1.1 (10-12-09)  